Research Article

Differential Electroanalysis of Dopamine in the Presence of a Large Excess of Ascorbic Acid at a Nickel Oxide Nanoparticle-Modified Glassy Carbon Electrode

Table 3

Comparison of analytical parameters for the detection of DA and AA at GCox/nano-NiOx with other modified electrodes.

MaterialsTechniqueAnalyteLinear range (μM)LOD (μM)Sensitivity (μA cm-2/μM)Reference

OMC/Nafion/GCEaDPVDA1–900.54.76[61]
AA40–800200.496
Ni@poly-1,5 DAN/GCbSWVDA100–5000.0110.583[62]
AA100–5000.00.751
PEDOT-modified Ni/Si MCPcDPVDA12–481.55.40[63]
AA20–1400100.539
Ni-Meso-PANI/GCEdDPVDA10–3006.93.78[64]
AA10–3007.12.71
Bi/BiVO4PECeDA0.05–1000.0080.199[65]
AA0.2–1180.090.194
GCox/nano-NiOxSWVDA80.0-8000.690.329This work
AA1160-11600180.062

aOrdered mesoporous carbon (OMC)/Nafion composite film; bNickel nanoparticles dispersed at poly1,5-diaminonaphthalene; cNi/silicon microchannel plate (Ni/Si MCP) electrode modified with poly(3,4-ethylenedioxythiophene) (PEDOT); dTransition metal ion-exchanged mesoporous polyaniline; ePhotoelectrochemical.