Research Article
Effect of Parametric Uncertainties, Variations, and Tolerances on Thermohydraulic Performance of Flat Plate Solar Air Heater
Table 1
Range and baseline values of various design parameters.
| Parameter | Values |
| Transmittance-absorptance product for the absorber plate-glass cover combination, | 0.8 (single glass cover) | Gap between the absorber plate and glass cover, | 40–80 mm [10] | Collector slope, | 40° (winter), 25° (year round operation), 0° (summer) | Insulation | Foamed polystyrene or glass wool | Thermal conductivity of insulation material, | 0.037 Wm−1K−1 | Insulation thickness, | ≥50 mm | Glass thickness, | ≥4 mm | Thermal conductivity of glass, |
0.78 Wm−1K−1 | Long wave emissivity | | Glass cover (window glass), | 0.88 [20] | Absorber plate, | 0.95 (black paint), 0.1 (selective coating) | Duct surface | 0.9 | Absorber plate (duct side) | 0.9 [21] | Length of the collector duct, | Baseline value = 2 m | Duct height, | 5–20 mm, baseline value = 10 mm | Width of duct, | 1 m |
|
|