Research Article

Symmetric Compound Parabolic Concentrator with Indium Tin Oxide Coated Glass as Passive Cooling System for Photovoltaic Application

Table 5

Variation in total energy flux concentration on the entire PV module with and with HRW as function of incidence angle.

Incidence angle (°)Sum of all energy flux concentration for the entire PV module area
PV module with the CPC but without HRWPV module with the CPC and HRW

056.8455.61
558.2652.54
1059.1653.12
1557.5651.62