Abstract

Detection of explosives, explosive precursors, or other threat agents presents a number of technological challenges for optical sensing methods. Certainly detecting trace levels of threat agents against a complex background is chief among these challenges; however, the related issues of multiple target distances (from standoff to proximity) and sampling time scales (from passive mines to rapid rate of march convoy protection) for different applications make it unlikely that a single technique will be ideal for all sensing situations. A number of methods for spanning the range of optical sensor technologies exist which, when integrated, could produce a fused sensor system possessing a high level of sensitivity to threat agents and a moderate standoff real-time capability appropriate for portal screening of personnel or vehicles. In this work, we focus on several promising, and potentially synergistic, laser-based methods for sensing threat agents. For each method, we have briefly outlined the technique and report on the current level of capability.

1. Introduction

Real time detection of explosives and explosive devices continues to represent a major challenge for US and allied military forces in conflict areas throughout the world. Over the last decade or so, there have been a number of review articles that have addressed this subject from a variety of perspectives [16]. One of the clear outcomes from this body of work is that the ability to deter, predict, detect, respond to, and mitigate both improvised as well as conventional explosive threats is an issue from both a military and homeland security perspective. Explosives represent only one area of concern, as the same sensing technology could be easily adaptable to the general class of threat agents that includes nuclear, biological, and environmental toxins.

The ideal detection system for threat agents, whether these threats are explosives, chemical and biological agents, or illicit drugs, would possess high sensitivity (i.e., be capable of detecting threats present only at trace levels), be able to discern a threat amidst a real world background, possess a standoff capability, be straightforward to operate, and possess a real time sensing potential [119]. This last operational criterion will be critical whether the sensor is deployed at a military checkpoint, for airport security, or for any other domestic application where impeding the flow of commerce is an issue. Although such an ideal sensor system does not currently exist, there are a number of optically based techniques that, individually, possess one or more of these operational characteristics [123].

Consider that threat signatures are likely to come in two broad categories. Using explosives as an example, low vapor pressure solid and liquid residue on an automobile door or door handle left behind by someone who has recently handled explosives represents one type of signature. The second broad class of threat signatures consists of vapor emissions due to volatile solvents, impurities, and decomposition products naturally occurring in explosive material. These explosive related volatile organic compounds (VOCs) are collectively referred to as “the explosive bouquet” and are believed to represent the same signature used by explosive-trained canines for sensing the presence of an explosive [719, 2427]. Also included in this vapor signature category is the notion of a “breath test” to determine exogenous chemicals in exhaled breath [28]. Exogenous chemical spot breath measurement methods are already widely used within some governmental agencies and/or law enforcement communities. Evidentiary breath alcohol determination and EPA environmental exposure assessment studies represent two such examples [28, 29].

From a sensing perspective, individuals who have handled or have been exposed to threat agents (inhalation, ingestion, and dermal exposures are common routes) that contain a mixture of VOCs (such as a TNT-based explosive) will exhale these compounds for some time after exposure. Indeed, there have been a number of studies investigating the time profile for breath elimination of VOCs [28, 29]. Less volatile threat agents are often metabolized, ultimately leading to the production of volatile biomarker compounds. These biomarkers are typically quite sensitive and specific to a particular agent. Moreover, the volatile biomarkers cannot be disguised from an appropriate analytical measurement any more than an impaired driver can disguise the amount of alcohol in their breath.

Detection of threat agents will necessarily require a sensor able to monitor both particle and vapor signatures simultaneously. Again, there are several optical techniques which, when combined, could potentially produce an integrated sensor system possessing a high sensitivity towards threat agents as well as the ability to discriminate these threat species from a complex background signal at moderate standoff distances (1 m < < 10 m) and in real time. For example, cavity ring-down laser absorption (CRD or CRDLAS) spectroscopy has demonstrated a great deal of potential for sensing at short (<1 m) distances. Indeed, there have been a number of review articles, books, and treatises that have focused on this powerful spectroscopic technique [20, 21]. There have also been a number of reviews that have focused on Raman scattering and laser-induced-breakdown spectroscopic (LIBS) methods for standoff sensing applications [16, 22].

Within the Arkansas Center for Laser Applications and Science (ArCLAS), we have created a number of unique sensing capabilities over the last decade. Here we examine the performance of several of these sensor systems with a potential standoff threat detection capability in some detail, including an enhanced LIBS method, in which a collinear CO2 TEA laser pulse is superimposed in time and space with the tripled or quadrupled output from an Nd:YAG laser as well as an enhanced Raman-based method known as stimulated Raman adiabatic passage or STIRAP [30]. In addition to the spectroscopic sensing capability, we have also developed a capability to generate molecular signatures for threat agents of interest. We will begin with a brief discussion of the molecular signature effort by examining several examples relevant to explosive detection.

2. Molecular Signatures

Every optically based sensing method requires a priori knowledge of the molecular signature, or in this case, wavelength specific signature, for the species of interest. For many species, high quality, low spectral resolution (~0.1 cm−1) databases are sufficient. There are literally person-decades of effort contained in these infrared databases [31]. And, for many small molecules, spectral resolution of this magnitude is sufficient for achieving rotationally resolved vibrational spectra. When greater specificity or discrimination is required, high spectral resolution signatures are needed. Fortunately, there are also a number of high quality, high spectral resolution databases that have been developed and maintained. The HITRAN database is one example of such a database [32, 33]. However, many of these high-resolution databases contain spectral information for a limited number of species. For example, although the current HITRAN database contains over 7 million rotationally resolved transitions, only 47 different molecular species (and their isotopic variations) are represented [32, 33]. Nevertheless, most of the major species relevant for atmospheric analysis are contained in this high resolution spectral database.

In the case of explosives, it is often not the energetic compound that is of interest, but rather a volatile impurity or perhaps a photo fragment. For TNT-based explosives the volatile explosive bouquet consists of toluene, nitrobenzene, and the mononitrotoluene (MNT) [34]. A detailed database containing the high resolution spectral signature for such compounds is extremely limited, in part due to the fact that each is an asymmetric top and is expected to exhibit fairly complex spectra when examined at high spectral resolution and room temperature conditions.

For many bouquet species, again, high quality low resolution infrared data is widely available [3546]. To a significant extent, we have used these databases as a starting point for our high resolution infrared measurements. All of the infrared measurements shown here were collected using the spectrometers shown in Figure 1 (a detailed description of the spectrometer is available in the literature [47, 48]). For the longer wavelength measurements, various Pb-salt diode lasers were utilized as the primary light source. At shorter wavelengths, a combination of Pb-salt diode lasers and cw external cavity quantum cascade lasers (QCLs) was used.

Consider the snippet of rovibrational spectrum for nitrobenzene shown in Figure 2. This particular trace was recorded at a spectral resolution of 0.003 cm−1 with a Pb-salt diode laser. The top trace represents the signal channel and contains the spectral data for nitrobenzene. The middle trace is from a 1′′ solid Ge etalon and is used for calibration purposes. The bottom panel contains a reference gas used to provide absolute frequency calibration of signal. In this spectral region, CO2 is often used as a reference gas and the trace shows a series of well-known rovibrational transitions for the various isotopic varieties of CO2. Although this snippet is less than 2 cm−1 in frequency space, there are 17 clearly defined nitrobenzene absorptions. To date, dozens of these nitrobenzene snippets have been observed and hundreds of rotationally resolved nitrobenzene transitions have been recorded and tabulated in the 14-micron region.

While a comprehensive table of nitrobenzene rovibrational absorptions near 700 cm−1 has been generated, we have not been successful assigning a complete set of rotational quantum numbers to these transitions. Certainly, the complex nature of the spectra contributes to the challenging nature of generating accurate assignments. Another contributing aspect however is the discrete tuning limitation associated with Pb-salt diode lasers and this limitation is particularly true at longer wavelengths where He cooled cryogenic cooling is necessary for laser operation. Continuous tuning is accomplished over a single longitudinal mode of the laser. Helium cooled diodes typically possess very short longitudinal mode tuning ranges in frequency space (<1 cm−1 in many cases) with adjacent modes being separated by 3–5 cm−1.

The molecular signatures for species associated with RDX-based explosives do not typically contain nitro groups [32, 33, 49]. In fact, based on a series of GC/MS measurements [32, 33, 49], the explosive bouquet for RDX-based contains cyclohexanone, ethylhexanol, and isobutylene. Of these compounds, isobutylene lends itself to high resolution spectroscopic study most readily. Several rovibrational bands of isobutylene occur at shorter wavelengths and these bands have been successfully investigated with Pb-salt diode laser technology. For example, the band at 11 microns has been observed, analyzed, and assigned, at least for the torsion-free vibrational bands [50]. Some headway has also been achieved on the band centered near 1380 cm−1 [51]. What is interesting about these two bands is the observed regularity associated with the P, Q, and R branches.

Consider the FTIR spectrum for this band shown in Figure 3. This particular band was recorded at a spectral resolution of only 0.125 cm−1. Even so, there appears to be a series of rotationally resolved transitions in both the P and R branches of the band.

At higher spectral resolution, it becomes clear that there is additional structure associated with each spectral feature in the P and R branches. In Figure 4, a spectral snippet from the same region taken with Pb salt diode laser is shown. In the top panel of Figure 4, three sets of doublets are observed in the isobutylene signal. The spacing of the doublets is approximately 0.5 cm−1 (from doublet center to doublet center). A similar spacing is observed in the lower resolution FTIR spectrum in Figure 3 and corresponds to the spacing between adjacent spectral features in the P and R branches.

Rotational assignments have been tentatively made using a spherical top type model and, with these assignments in hand, a series of effective molecular constants were determined for the band [51]. A complete listing of these constants is given in Table 1.

Rotational constants for the ground vibrational state of isobutylene were originally determined using microwave spectroscopic methods and first reported over forty years ago [52]. The set of rotational constants determined from the microwave measurements are  cm−1;  cm−1; and  cm−1 [52]. Unfortunately, there is really no direct way to correlate the effective rotational constant in Table 1 with the rotational constants reported by Laurie and coworkers. Such correlations can really only be obtained by fitting the rovibrational data to an oblate asymmetric top set of energy expressions. Although the goal for any high resolution molecular spectroscopic study should necessarily include such correlations, the central point of this paper is to highlight a strategy to identify appropriate spectral regions for optical detection of explosive bouquet species. Parenthetically, we are working to fit the rovibrational data for the 1382 cm−1 band of isobutylene so that these correlations can be made.

In fact, this band has also been examined with a Daylight Solutions mode-hop-free QCL laser spectrometer. The entire band has been subsequently recorded at spectral resolutions ranging from 0.1 to 0.001 cm−1 [53]. A detailed analysis, using a more appropriate asymmetric top model, has been performed resulting in a unique , , quantum assignment for each of the observed spectral transitions [53].

3. Stimulated Raman Adiabatic Passage (STIRAP)

Laser induced fluorescence is a very sensitive technique for monitoring molecular species. Unfortunately, it is not very useful for many of the species of interest for threat detection in the atmosphere. These relatively small molecules frequently require excitation in the ultraviolet and there are many other trace species in the atmosphere that are also excited in the uv, significantly complicating result interpretation. Techniques that use two photons for excitation allow much more selectivity in targeting the molecule of interest but at a cost of more instrument complexity. One such technique is Stimulated Raman adiabatic Passage or STIRAP.

STIRAP was developed and first described by Gaubatz et al. [54]. A brief outline of this method is given here. In its most basic form, STIRAP requires three energy levels of an atom or molecule with good electric dipole coupling between an initial state and an intermediate state as well as good electric dipole coupling between the intermediate state and a final state (see Figure 5).

In order to perform ordinary sequential excitation or stimulated emission pumping (SEP) the first laser (pump) excites the molecule from level to level after which the second laser (Stokes) excites from level to level . STIRAP differs in that the order of the laser pulses is reversed, albeit with partial temporal overlap. This counterintuitive sequence is capable of transferring 100% of the atoms or molecules from the initial state to the final state, whereas SEP transfers a smaller fraction to the final state (much smaller when weaker laser pulses are used). STIRAP can be performed with any ordering of the atomic/molecular energy levels with lambda, Λ, (initial and final states lower than the intermediate state) and ladder (final state higher than the intermediate state which is higher than the initial state) being the most common.

Diagrams outlining the STIRAP process in the lambda ordering of energy levels are shown in Figure 5. In the panel on the left the wavelengths of the lasers are tuned to correspond precisely to the differences in the energy levels of the atom or molecule and efficient transfer from state to state can occur. This is the desired arrangement for the target molecule. In the panel on the right (off-resonance), the energy/photon of light coupling states and () is less than the difference in energy between and by an amount . Likewise, the energy/photon of light coupling states and () is less than the difference in energy between states and by an amount . The total mismatch for the two-photon transition from to is .

Within the rotating-wave approximation, the quantum mechanics of a three-state system can be modeled by the following set of equations: where , , and represent the populations of the states , , and ; , , and , represent time derivatives of , , and ; and and represent the time dependent Rabi (angular) frequencies of the laser pulses. The solution to (1) with the pump and Stokes laser pulses of Gaussian temporal shape shown in Figure 5 is shown in Figure 6(b). The population of state starts at zero and increases to 1 while the pump and Stokes pulses overlap. When the pulses have passed, the population of state differs negligibly from unity. It is interesting to note that the state remains relatively unpopulated. This is an advantage since state can fluoresce which could lead to a decrease in the population transfer efficiency to state . The results shown in Figure 6 have been reproduced experimentally on a number of atomic and molecular species [5457].

One of the advantages of using STIRAP to study molecules in the atmosphere is that the method is robust with respect to variations in the timing of the pulses. Figure 7 shows the fraction of molecules transferred to state as a function of the temporal delay of the pump pulse behind the Stokes pulse. In this solution to (1) the integrated Rabi frequencies of the laser pulses was set equal to 20 radians and the pulse widths of the lasers were arbitrarily set to 62 ps. The transfer efficiency remains above 90% for delays between 31 and 82 ps (a range greater than 80% of the pulse width). While the width of the pulses in this calculation is arbitrary, the result of 80% is not. When the integrated Rabi frequencies of the laser pulses is 20 radians, the transfer efficiency to state remains above 90% for a range of greater than 80% of the laser pulse width, independent of the laser pulse width. The robustness of the STIRAP transfer efficiency with respect to laser pulse timing delay is ideal for propagation through the atmosphere; atmospheric dispersion could potentially change the delay of one pulse relative to another. Although the dispersion could be incorporated into the delay between the pulses for measurements at a certain distance, the robustness of the method with respect to this delay makes measurements at a larger range of distances possible.

The vast majority of published STIRAP papers have been done on atomic/molecular beams or ultracold gases. These sample arrangements eliminate collisions and Doppler broadening which makes it possible to use continuous wave lasers or Fourier-transform-limited nanosecond lasers. Inasmuch as collisions between the target atom/molecule with other atoms or molecules spoil the STIRAP transfer efficiency, when collisions are present the STIRAP transfer must be complete in a time shorter than the mean time between collisions. If STIRAP is to be performed at atmospheric pressure, the process must be complete in a time shorter than a few tens of picoseconds.

In order to demonstrate STIRAP on a vapor (as opposed to an atomic beam or ultracold gas), we performed STIRAP on a vapor of sodium using coherent lasers with pulse widths of several picoseconds. The initial, intermediate, and final states were chosen to be the 3s, 3p (2), and 5s states, respectively. Figure 8 shows STIRAP in sodium. The population transfer efficiency in the STIRAP ordering of laser pulses is about a factor of two larger than the SEP ordering. In a paper to be published, we show that with strong laser pulses the maximum measurable STIRAP efficiency is slightly more than a factor of two greater than the SEP transfer efficiency when a grating-based spectrograph is used to collect the fluorescence. This rather small gain in signal is because the spectrograph collects light at the center of the lasers where the STIRAP transfer efficiency is 100% as well as the outer edges of the laser pulses where the pulses are much weaker. In other publications we demonstrate STIRAP transfer efficiencies that are more than a factor of two larger than the SEP transfer efficiency. Details of the work can be found in [58, 59].

We have also demonstrated STIRAP on target atoms in a buffer gas at atmospheric pressure. This was done on sodium vapor in an argon buffer gas. Graphs similar to Figure 8 were collected at several argon pressures up to atmospheric pressure. From each of these graphs, the STIRAP signal (highest at negative Stokes delay) and SEP signal (measured at positive Stokes delay toward the right of the figure) were determined and a STIRAP/SEP ratio was calculated. In Figure 8 this ratio is approximately equal to 2. Figure 9 shows this ratio as a function of argon pressure. If collisions were to interfere with the STIRAP process, the STIRAP/SEP ratio should drop as the argon pressure increased. The figure shows that there is no drop in the STIRAP transfer efficiency even up to atmospheric pressure. Additional details can be found in [60].

Such experiments represent not only the first picosecond STIRAP measurements, but also the first measurements on target species in a buffer gas beyond a 1 torr sample gas pressure. The total standoff distance for these measurements was less <1 m. However, with larger optical collection devices, which are available commercially, we believe such detection distances can be easily extended to 50 m. Certainly, such standoff capability has been achieved with other Raman methods [61]. A major hurdle from our perspective was achieving STIRAP at ambient conditions, that is, atmospheric pressures and room temperature. Finally, once a significant standoff capability has been realized, this method should prove invaluable in numerous applications from military defense related problems to environmental monitoring.

4. Infrared Enhanced Dual Pulse LIBS

Laser-induced breakdown spectroscopy (LIBS) provides sensitive, multi-elemental, and real time chemical analysis [62]. Because of its rapidity, small sample size, noncontact nature and freedom from sample preparation, LIBS has become a common technique for elemental analysis in a variety of applications, including analysis of rocks, art work, quality control in metal alloys and examination of the surface oxidation of inorganic and organic materials. The technique employs an intense, short duration laser pulse to ablate the sample, generating a rapidly evolving (ns-μs scale) plasma. The ablation parameters are highly sample dependent and the resulting plasma plume is a transient, emissive mixture of atoms, ions and molecules in various states of excitation. In addition to evolving rapidly in time, the plasma is spatially inhomogeneous in composition and temperature. The plasma’s thermal emission is collected and analyzed, typically with CCD or ICCD-based spectrographs. Relative elemental limits of detection are typically in the tens to low hundreds of ppm [63]. LIBS is ideally suited for remote sensing and hazardous materials applications because of its ease of use and because it requires little or no sample preparation. Nonetheless, the technique is limited by matrix effects and poor precision [64], in part because there is no sample preparation.

Although the first mention of DP LIBS (dual-pulse LIBS) for elemental analysis came from Malmstadt in 1969 [65], it has experienced a resurgence recently [6672]. The technique provides enhanced LIBS signal via modification of the sample, atmosphere or plasma through the addition of a second laser pulse. DP LIBS pulse separations are typically on the order of a few microseconds, though separations may be as short as a few picoseconds in the case of femtosecond pulses. Relative pulse geometries are classified as either collinear or orthogonal, with the former lending itself to standoff work [7377]. The DP LIBS technique has demonstrated signal enhancements of approximately an order of magnitude in some cases, though the values vary depending on the substrate and the particular element being investigated. Standoff applications frequently employ a laser pre-spark to generate a rarefied environment into which a subsequent analytical plasma can expand with minimal interference from the rarefied atmosphere (see [78]). The largest improvements have been obtained on pure metal substrates, while other substrates give enhancements that are less impressive.

The enhancement mechanisms of DP LIBS have been postulated to involve: direct coupling of the second pulse into the plasma created by the first pulse (i.e., plasma “reheating”), target heating by the first pulse, thus allowing enhanced ablation by the second pulse and higher resulting plasma temperatures and formation of a thermally hot, low number density atmosphere above the sample surface by the first pulse, thereby altering the development and propagation of the analytical plasma created by the second pulse [31]. The latter scenario is particularly interesting due to the improved spectral line shape, improved signal to background ratio, and slower line shape and intensity evolution observed by Colao et al. [79]. Because of the reduced shielding, DP LIBS may also increase the ablation efficiency and the reproducibility of the analytical plasma. The dual-pulse phenomenon is of interest to the standoff laser sensing community as signal is typically at a premium in this geometry; signal collection falls off with the square of the standoff distance necessitating either larger optics or more signal spectral radiance. Note, however, that the exact relationship between the detection limit and standoff distance is also a function of the noise source and type.

Standoff LIBS, as well as DP LIBS have been investigated for the detection of explosives. For example, Gottfried et al. coupled PLS-DA (partial least squares discriminant analysis) and DP LIBS at standoff distances of 25 m to discriminate RDX ≥ 96% of the time on a variety of substrates (travertine and wood surfaces gave lower discrimination—40% and 88%, resp.) [80]. The discrimination was based on the ratios of 83 atomic and molecular emission lines. Even more recently, Waterbury et al. demonstrated infrared enhanced standoff detection of explosives at tens of meters using modest telescope optics [81].

As energetic materials are typically organic in nature, their decomposition byproducts are simple, light, and very stable molecules (N2, H2O, CO, CO2). In addition to C, H, O and N atomic emission, the laser ablation of energetic materials also generates molecular species such as CN and C2 observable by optical emission spectroscopy. Because of air entrainment in the plasma and subsequent chemical reactions, it is difficult to distinguish between strictly sample-derived C, N, O, or CN emission and that resulting from the incorporation of air in the plasma and subsequent chemical reactions between air and sample-derived species. In the laboratory, air is excluded by flushing with a noble gas, while standoff applications profit from DP LIBS configurations where a prespark can reduce the number density of the surrounding atmosphere. A general understanding of the origin of the organic molecule-derived signals is crucial if these are to be used for explosive identification [8285].

Our lab has investigated DP LIBS for potential to enhance standoff detection of explosives. Though Nd:YAG wavelengths dominate the dual-pulse literature, other laser combinations have been employed. Our research has focused on the use of a secondary CO2 laser pulse to reheat and prolong the plasma produced by an initial Nd:YAG-induced spark. It is well known from the laser cutting and welding industry that a 10.6 μm laser couples very effectively into the laser-generated plasma, creating “plasma shielding” of the target. Thus, the CO2 laser should couple into the plasma’s free electrons through inverse bremsstrahlung. Although this DP LIBS configuration would not benefit from atmospheric exclusion, the increased signal may improve standoff detection. Of course, selectivity is also important to explosives identification, but this is beyond the scope of our initial work.

Preliminary 1.06 μm + 10.6 μm DP LIBS experiments were reported by Killinger, Allen, and coworkers in 2007 using an alumina target with Na, Mg, Fe and Si impurities (≤0.08% as oxides) [86]. The experimental arrangement is given in Figure 10.

Results for aluminum and magnesium from this preliminary study are given in Figure 11. For the single pulse experiment, a Q-switched Nd:YAG (Big Sky CRF200, 50 mJ/pulse, 5 ns, 5 Hz, ) was focused to a 1 mm diameter spot on the alumina target. Plasma emission was focused onto a 300 μm inner core fiber optic cable coupled to a spectrograph (Ocean Optics LIBS2500, 200–980 nm). In the dual-pulsed experiments, a high power, CO2 TEA laser beam (Lumonics Model 920, 1.3 J, 5 Hz) was fired at the alumina target in conjunction with the Nd:YAG laser. The laser operated at 10.6 μm with a 100 ns spike followed by a 5 μs nitrogen-fed tail. The CO2 pulse was defocused to a fluence of 0.050 J/mm2 on the target surface. A digital delay generator was used to time the pulses. A fast Si photodiode and photon drag detector were used to monitor the Nd:YAG and CO2 pulses, respectively. The angular separation of the Nd:YAG and CO2 beams was about 30 degrees, with the LIBS collection optics oriented at an angle of about 20 degrees to the CO2 beam as shown in Figure 10.

Several aluminum peaks are evident in the spectra in Figure 11. The strongest lines are around 394.40 nm and 396.15 nm, although they are poorly resolved in the figure due to the low spectrometer resolution. The unlabeled peaks in other regions of the spectrum correspond to Mg, Na, and H impurities in the sample.

The infrared enhancement factor is defined here as the ratio of the peak heights for the enhanced signal (Figure 11) to the corresponding peak heights for the Nd:YAG LIBS signal (Figure 11) after subtracting the remaining background continuum. Although this ratio is only a crude estimate of the true gain that can be realized, it is useful for demonstrating trends in the signal enhancement. This factor is 5 to 20 for emission from atomic species while it is approximately 200 for ions. Neutral atomic atmospheric components have large signal enhancements because their spectrum is very weak for standard Nd:YAG LIBS, so any increase with the infrared laser creates a substantial enhancement factor. Several additional comments should be made about the experimental set-up: No LIBS signal or visible plasma was observed with the CO2 laser alone, that is, the CO2 intensity was below the plasma breakdown threshold and the collection time for the spectrometer was several ms so that significant atmospheric species were excited and detected. Given that the second pulse was 10.6 μm, the enhancement mechanism here is best understood as a continuation of the plasma by the second laser pulse rather than a reignition as discussed in Pershin [67]. It is also interesting to note that no enhancement occurred when the shorter Nd:YAG pulse occurred in the midst of the much longer CO2 pulse, perhaps suggesting decreased ablation efficiency as a result of the onset of plasma shielding and laser supported detonation when the Nd:YAG ablates the sample in the bath of mid-IR irradiance.

Subsequent work in our laboratory has focused on the benefits of the infrared reheating pulse for molecular emission measurements in LIBS plasmas. Although it is generally assumed that the primary source of CN species in the LIBS plasma subsequent to the ablation of organics is chemical reactions with air [78], it has been suggested that UV or femtosecond ablation creates diatomic molecules directly, potentially maintaining the information about bond structures in the original molecule [83, 84]. Presumably, as the plasma evolves, more non-native CN is created through atmospheric reactions. Ma and Dagdigian have modeled the process, tracking molecular and atomic populations and their excitation state distributions [85]. Several groups conclude that emission from native CN bonds created by “selective” photolysis of chemical bonds in the ablation process should give rise to a single exponential-type decay of CN intensity, while recombination effects should lead to a more complex ingrowth over tens to hundreds of nanoseconds followed by a decay as the plasma cools and dissipates. Thus, at early times, it may be reasonable to assume that molecular emission originates from native molecules.

With this in mind, the benefit of infrared enhancement in early plasma molecular emission was investigated in a bench-top setting. Note that this work focuses on S/N rather than selectivity as the former is simpler to quantify. Long-pulse CO2 lasers are not appropriate for enhancing molecular emission, as most of the energy couples to the plasma at times where non-native emission would dominate. Thus, a 40 mJ TEA CO2 laser (Edinburgh Instruments) with an ~50 ns pulse width was used for the infrared reheating pulse. Pressed pellets of nitrobenzoic acid sample served as a convenient molecular stand in for TNT (Figure 12). Primary ablation was with 5 mJ of 355 nm from a Quantel YG981E. The modest UV energy was used to keep the laser flux at the sample low (0.6 J/cm2). 40 mJ of 10.6 nm CO2 was brought in at 70 ns, with a spot size of ~1.5 mm, creating a flux of 0.02 J/cm2. CN violet band signal to background ratios were measured as a function of time with a gated ICCD (Andor iStar, 50 ns gate width) coupled to a 0.5 m Czerny-Turner spectrometer (Andor Shamrock).

Although S/B is not a perfect stand-in for signal to noise ratio without knowledge of the background noise character, Figure 13 suggests that the reheating due to the infrared pulse likely decreases the ability to perceive the molecular emission at early times. Plasma imaging suggests that the infrared pulse couples into the plasma efficiently in this arrangement (Figure 14). Once again, this is likely an inverse bremsstrahlung process that directly heats the electrons responsible for the LIBS continuum background. Note that the images are independently scaled—that is, absolute intensities cannot be inferred, but relative morphology can. Given that the increase in brightness is at the edge of the plasma, it is likely that the reheating pulse has a low penetration into the plasma, with the heat diffusing throughout the plasma subsequently. Comparison of Figures 14 and 15 suggests that the extent of the infrared energy’s diffusion is actually fairly limited, at least on this brief timescale.

In light of these data, we would not expect CO2 laser reheating to improve native molecule-based detection and discrimination of explosives. It should be noted that the arrangement used with our double pulse work is unique in that we reheat with a mid IR pulse and we couple the reheating pulse in with only a 100 ns delay. The latter is dictated by our interest in native molecular signals. While we have observed enhancement of atomic signals using long-pulse CO2 TEPS and portable spectrometers, this measured enhancement should be qualified. First, the enhancement is most significant for those species that benefit most from a more energetic plasma (e.g., ionic species). Second, enhancement of the signal does not necessarily improve detection as noise “enhancement factor” could match or exceed the signal enhancement if plasma continuum (i.e., bremsstrahlung and recombination emission) is the limiting noise, as is commonly the case in LIBS measurements, especially when using intensified detectors. Finally, as the LIBS plasma size and time evolution is likely different between single pulse and CO2-reheated plasmas [87], the analytical performance of each technique should be optimized separately before comparison. Such a full comparison is quite complex and beyond the scope of this initial report. The use of a CO2 laser pulse as a preparatory prespark (in contrast to the reheating described here) pulse may also be of interest. It remains to be seen if a CO2 prespark can create a low number-density atmosphere for the subsequent analytical plasma; this concept is currently being investigated and will be addressed in future publications.

5. Conclusion

Two promising techniques for standoff detection have been reviewed and discussed. One method, STIRAP, has been limited in the past to species in molecular beams or subatmospheric gas samples (low-pressure bulk gases). However that method, at least in the picosecond time regime, has now been successfully demonstrated on gas samples at atmospheric pressures. Although STIRAP has yet to be demonstrated on species associated with threat agents, one of the major hurdles, operation at atmospheric pressures, has been accomplished. Infrared enhanced dual pulse LIBS is further along in that it is currently being used to detect explosives or, as discussed in this work, explosive simulants. However there is still a great deal of questions associated with the infrared enhancement and further studies will most likely be required before this method can achieve its full potential as a viable standoff detection method for explosives and other threat agents.

Disclosure

The material presented here has been approved as Distribution A: Unlimited Public Release.

Conflict of Interests

The authors declare that there is no conflict of interests regarding the publication of this paper.

Acknowledgments

The authors would like to acknowledge the efforts of the graduate students and postdocs from the Spectral Signatures, Multiphoton and LAMP laboratories within ArCLAS at Arkansas State University. This work was funded by the U.S. Army RDECOM CERDEC Night Vision and Electronic Sensors Directorate under Contract nos. #W909MY-09-C-0001 and #W15P7T-10-C-A012.