Abstract

A Brewster angle reflection imaging apparatus is demonstrated which is capable of detecting hidden water-filled voids in a rubber tile sample. This imaging application simulates a real-world hull inspection problem for Royal Canadian Navy Victoria-class submarines. The tile samples represent a challenging imaging application due to their large refractive index and absorption coefficient. With a rubber transmission window at approximately 80 GHz, terahertz (THz) sensing methods have shown promise for probing these structures in the laboratory. Operating at Brewster’s angle allows for the typically strong front surface reflection to be minimized while also conveniently making the method insensitive to air-filled voids. Using a broadband THz time-domain waveform imaging system (THz-TDS), we demonstrate satisfactory imaging and detection of water-filled voids without complicated signal processing. Optical properties of the tile samples at low THz frequencies are also reported.

1. Introduction

The transparency of many dry, nonconductive materials to radiation at THz frequencies has allowed new applications of broadband THz pulses to nondestructive evaluation (NDE) and the imaging of concealed objects and surfaces [13]. THz radiation is electromagnetic radiation found in roughly the 0.1 THz to 10 THz range, between the microwave and infrared portions of the electromagnetic spectrum. THz radiation is nonionizing and has submillimeter wavelength, making it a competitive imaging technology to X-rays without having the associated health risks [4]. For example, it has proven suitable for imaging defects in foam insulation within the fuel tanks of the NASA space shuttle [5]. THz reflection tomography [6] has been demonstrated using coherently detected THz pulses and has been used for applications ranging from the imaging of delaminations [7] and under paint corrosion [8, 9] to art conservation [10]. THz radiation is also extremely sensitive to water which absorbs it strongly in the far infrared. This has been exploited to image water content and diffusion in cork [11] and to identify concealed water-filled voids [7].

The motivation for this project was to investigate the feasibility of a reflection imaging system for the hull inspection of Royal Canadian Navy Victoria-class submarines (Figure 1). In order to operate with enhanced stealth, these vessels are fitted with an acoustic rubber tiling for the purposes of absorbing emanating noise and providing sonar cloaking. The design of the acoustic tiles generally features internal voids for enhanced acoustic absorption. These tiles, as well as a connective grouting compound, thus form an opaque covering over virtually the entire hull surface.

In evaluating the integrity of the pressurized hull, it is of paramount importance to discern states of corrosion of the underlying steel in addition to delamination and seawater ingress within the tile voids and grouting interfaces. A nondestructive means of on-site inspection with THz radiation has therefore been sought after. Such nondestructive evaluation would be done in practice from the outside surface of the hull, with the radiation reflecting off the metal subsurface or intermediate tile layers.

It has been observed that, as a prelude to further corrosion, sites of water ingress are typically characterized by the internal tile voids becoming flooded with seawater. The ability to detect hidden water-filled voids could therefore constitute an early warning for corrosion, and an easy signal for tile replacement and regrouting.

Due to security reasons that precluded the use of actual tile samples, representative rubber tile samples or “analogue tiles” were used in the laboratory for this study. Each of the tile samples was approximately 4 inches square by 1 inch thick and consisted of three laminated layers (see Figure 5, oval inset). Engineered voids were simulated by holes drilled into the middle layer.

2. THz Apparatus

The THz-TDS system used in this work was a high speed Picometrix T-Ray 4000 system, generating linearly polarized, pulsed THz radiation detected in an 80 ps window, with a bandwidth of approximately 2 THz, modified to operate at a 1000 waveforms/sec acquisition rate. The emitter and detector are fibre-coupled photoconductive switches, allowing the system to be easily mounted in a raster-scanning configuration for the imaging studies.

Example THz signals from the THz-TDS system are presented in Figure 2 for transmission through both air and analogue tile. The time-domain waveforms presented in Figure 2(a) were stitched from several waveform observations (80 ps duration) obtained from the device. After transmission through the tile sample, the initial THz pulse is delayed and strongly attenuated. A window of THz transmission for the analogue rubber can be seen in Figure 2(b) centered at approximately 80 GHz.

3. Imaging Experiments

The large refractive index and absorption of the analogue tile samples was extracted from transmission and reference time-domain measurements using the method presented in [12, 13]. The extracted absorption coefficient and refractive index are shown in Figure 3.

Transmission imaging scans were initially taken of the analogue sample tiles. A direct transmission image taken of the internal air-filled void structure of tile sample “A1-8” is shown in Figure 4 which was generated from waveform data captured at each position. The color map corresponds to the amplitude of the transmitted spectral content in the 0.01 THz to 0.10 THz range (highlighted in Figure 2(b)) computed from the Fourier transform of the time-domain data. Variation in transmission is primarily attributed to a nonuniform bonding glue application between layers. The two internal voids are clearly observable from transmission minima at their edges due to the deflection and subsequent trapping of the penetrating radiation.

The large refractive index of the analogue tiles leads to a large front surface reflection at normal incidence through air at THz frequencies. In addition for reflection imaging, the large absorption of the material diminishes the amplitude of collected signals which must pass through any absorptive layers twice before detection. For example, at 80 GHz and at normal incidence, the expected reflected intensity coefficient from the top surface of a water-filled void within our sample would be 0.0146, whereas the expected reflected intensity from the front surface would be greater by a factor of 9.5. A value of at 80 GHz [14] was used to estimate these values, along with the data of Figure 3.

Due to the large refractive index and strong absorption of the analogue tiles, we attempted reflection imaging at 80 GHz from the top rubber-rubber tile interface, located at a depth of approximately 0.25 inches below the top tile surface (see Figure 5, oval inset). Operating at the Brewster angle with TM-polarization minimized the front surface reflection and maximized signal penetration.

Brewster angle microscopy and imaging was developed to exploit dielectric contrast to probe surface interfaces [15], where it has been exceedingly successful at investigating even monolayers at surface interfaces [15, 16]. We employ the Brewster angle here to make our imaging set-up as insensitive as possible to the surface interface, while exploiting dielectric contrast to probe subsurface interfaces, which would otherwise be obscured by strong front-surface back reflections.

Our Brewster’s angle imaging apparatus is photographed in Figure 5. Off-axis parabolic mirrors (F/3) were used to focus the incident radiation into a narrow beam incident at the 80 GHz Brewster’s angle of 63°. The analogue tile samples were controlled in both horizontal directions using a pair of motorized translation stages, while the emitter and detector positions remained fixed.

Raster images of the analogue tile samples were produced by capturing individual waveforms as the sample was repeatedly repositioned at the focus. Using 1000 averages for each collected waveform, our system produced imaging scans at a rate of approximately 7 seconds per pixel. The coherent detection allowed for temporal alignment of the acquired waveforms in order for a particular depth of reflection to be selected. Temporal alignment was achieved from an estimation of the optical path length of a single-pass reflection of the beam at the first interface at Brewster’s angle. Raster waveform data was then used to produce gray scale sample images by first truncating the waveforms to a 25 ps window containing the peak of the reflected pulse, and subsequently extracting the integrated spectral content of the signal in the vicinity of 80 GHz through the use of a discrete Fourier transform.

Brewster angle reflection images of the sample tile “A1-8” are shown in Figure 6. Our image progression simulates the imaging effect of water ingress into the internal voids. To achieve this, a syringe was used to inject tap water into the voids until they were completely flooded. The progression in Figure 6 clearly shows the sensitivity of our technique to the detection of flooded internal voids in the sample tiles. The oblong appearance of the flooded circular voids is due to the oblique angle of incidence of the THz beam in the Brewster’s angle imaging configuration.

A particular advantage of imaging at the Brewster angle for this application is that those internal voids not contaminated by fluid ingress are invisible. This may be understood by considering the Brewster angle path of the THz beam illustrated in Figure 7 for the cases of rubber-rubber, rubber-air, and rubber-water interfaces. In particular, a beam which penetrates the top rubber layer and enters a void must exit the cavity ceiling at the angle of incidence (Figure 7(b)), which therefore implies total transmission by the time reversal of the Brewster property. Due to the low dielectric contrast between the tile layers, such near-optimal transmission is also observed at the contiguous rubber-rubber interfaces of the sample (Figure 7(a)). Reflected signals from the first interface therefore do not exhibit contrast between the uncontaminated voids and the contiguous analogue rubber media surrounding them. Upon fluid ingress into the voids, the total transmission property is no longer valid at the cavity interface, and the result is an increased reflected signal from the interface (Figure 7(c)).

We hypothesize that the mostly “dark” appearance of the water-filled voids is due to the destructive Bragg interference between the reflected flooded cavity interface and the front surface reflection, shown by the two dashed rays in Figure 7(c).

Front surface reflections are still encountered even when operating at Brewster’s angle in practice and are illustrated by the topmost dashed rays in Figures 7(a), 7(b), and 7(c). Despite the temporal alignment and truncation of our acquired waveforms, the reflected pulse windows still contained atmospheric “ringing” from the front surface reflected pulse. Interpreting this residual front surface signal as a noise floor for our apparatus, we obtain a signal to noise ratio (SNR) of 1.64 compared to the peak to peak amplitude of the reflected pulse from the void interface. This value is a lower bound for the SNR, as the front surface back reflection does not change significantly over the surface of the samples.

4. Conclusion

We were able to observe hidden water-filled voids through reflection mode imaging without complicated image processing. Successful water-filled void detection was possible at a depth of 0.25 inches beneath a layer of highly absorbing rubber in the laminated analogue tile sample. By operating at the Brewster angle, front surface reflections could be minimized with the added advantage of making uncontaminated voids invisible upon scanning.

A low dielectric contrast between the top and middle layers of the analogue rubber sample allowed for identical transmission between the contiguous rubber and cavity spaces at the depth of the first interface. We note that, for cases in which the dielectric contrast between the top and middle layer is significant, such identical transmission could theoretically be achieved via tuning of the reflection imaging angle through the Fresnel equations.

Conflicts of Interest

The authors declare that they have no conflicts of interest.

Acknowledgments

This research was carried out in the course of a larger collaboration between the authors’ research group at UNBC, the University of Alberta, McGill University, and Defence Research and Development Canada (DRDC). In addition to the authors, the members of this collaboration included Dr. David Cooke, David Valverde, and Lauren Gingras at McGill University and Rod McGregor at DRDC. The authors wish to acknowledge funding for this project from DRDC, NSERC, and the AITF Strategic Chair Program.