Ranges of B, Cd, Cr, Cu, Fe, Pb, Sr, Tl, and Zn Concentrations and Isotope Ratios in Environmental Matrices from an Urban Area Table 2 MC-ICP-MS operating parameters and measurement conditions for isotope ratio measurements
b . Table modified from Rodushkin et al. [
2 ].
Elementsa Configuration of introduction system Resolution mode Integration time (s) Sample uptake rate (mL·min−1 ) Dynamic mode configuration Cup configuration “δ -zero” reference standards Reported ratios L4 L3 L2 L1 C H1 H2 H3 H4 B Pumped micromist nebulizer, minicyclonic spray chamber, X-type skimmer cone Low 0.524 0.40–0.50 — — 10 B— — — 11 B— — NIST SRM 951a boric acid δ 11 BCd Aridus/Apex desolvating systems, self-aspirating microconcentric PFA nebulizer, X-type skimmer cone Low 0.524 0.04–0.06 107 Ag108 Cd109 Ag110 Cd111 Cd112 Cd114 Cd116 Cd117 SnNIST SRM 3108 Cd solution Lot 130116 δ 114 Cd108 Pd110 Pd112 Sn114 Sn116 SnZn/Cu Pumped micromist nebulizer, double spray chamber, H-type skimmer cone Medium 0.262 0.20–0.25 — 63 Cu64 Zn65 Cu66 Zn67 Zn68 Zn70 Zn— NIST SRM 976 Cu standard solution δ 56 Cu(64 Ni) IRMM-3702 Zn solution δ 66 ZnCr/Ni Pumped micromist nebulizer, double spray chamber, H-type skimmer cone/Apex desolvating systems, self-aspirating microconcentric PFA nebulizer, X-type skimmer cone High 1.262 0.05–0.25 Main — 52 Cr53 Cr54 Cr— 56 Fe— — — NBS SRM 979 Cr standard δ 53 Cr54 Fe Sub configuration — — — — — 60 Ni61 Ni62 Ni— Fe/Ni Pumped micromist nebulizer, double spray chamber, H-type skimmer cone Medium 0.262 0.20–0.25 54 Fe— 56 Fe57 Fe— 60 Ni61 Ni62 Ni— IRMM-014 Fe metal δ 56 Fe54 CrPb/Tl Aridus/Apex desolvating systems, self-aspirating microconcentric PFA nebulizer, X-type skimmer cone Low 0.524 0.04–0.06 — 202 Hg203 Tl204 Pb205 Tl206 Pb207 Pb208 Pb— NIST SRM 981 common Pb 206 Pb/207 Pb;208 Pb/207 PbTl: 1000 mg·L−1 elemental standard. Ultra scientific, North Kingstown, RI, USA; Lot L00709 δ 205 Tl204 HgSr Pumped micromist nebulizer, double spray chamber, H-type skimmer cone Low 0.262 0.20–0.25 82 Kr83 Kr84 Sr85 Rb86 Sr87 Sr88 Sr— — Sr carbonate NIST SRM 987 (NBS-987) Sr carbonate 87 Sr/86 Sr84 Kr86 Kr87 Rb
a One element is used as the internal standard for the second element, except for Ni and Ag which were only used as the internal standards. b RF power: 1400–1450 W. Coolant gas flow: 15 L·min−1 . Auxiliary gas flow: 1.4·L min−1 . Sample gas flow: 0.9–1.25 L·min−1 . Additional gas flow (N2 , Aridus and Apex) 0.01–0.02 L·min−1 . Ion lens settings: adjusted daily to obtain maximum sensitivity and signal stability. Zoom optic settings: adjusted daily to obtain maximum resolution. Number of blocks: 9. Number of cycles per block: 5. Number of integrations: 3–5. Amplifier rotation: left.