Research Article

A Substructural Damage Identification Approach for Shear Structure Based on Changes in the First AR Model Coefficient Matrix

Table 2

Changes in the first AR model coefficient matrix for Substructure III (10% damage).

DOF3rd story 2nd story1st story

Damage in 4th story
3rd story0.02290.00140.0006
2nd story0.00010.00010.0005
1st story0.00070.00080.0004

Damage in 3rd story
3rd story0.02220.02110.0006
2nd story0.02190.02170.0004
1st story0.00080.00160.0005

Damage in 2nd story
3rd story0.00000.00100.0012
2nd story0.00030.02240.0215
1st story0.00090.02180.0219

Damage in 1st story
3rd story0.00030.00010.0001
2nd story0.00070.00040.0004
1st story0.00020.00060.0230