More abundant elements ( g Kg−1 = parts per billion) revealed by the ICP on the solutions obtained from the water absorption test of samples with composition R and V20. Elements not reported were determined in quantity lower than 25 ppb.

Sample nameMgAlCaSiNaKFeBaSrPbS

R23113100220057861642011003417<25114<2519990
V2034093333168713956200971629439072732679921388