Research Article
Maternal Plasma and Amniotic Fluid Chemokines Screening in Fetal Down Syndrome
Table 5
Diagnostic values of chemokines in amniotic fluid.
| | Threshold value (pg/mL) | Sensitivity | 95% CI for sensitivity | Specificity | 95% CI for specificity | AUC | 95% CI for AUC | Std. error | value |
| IP-10 | >1152.5 | 0.8571 | 0.4868–0.9743 | 0.7857 | 0.5241–0.9242 | 0.8673 | 0.729–1 | 0.08 | <0.0001 | MPIF-1 | >189.62 | 1 | 0.6456–1 | 0.5 | 0.2679–0.7320 | 0.7857 | 0.6075–1 | 0.1 | 0.0041 | CXCL7 | >479.81 | 0.8571 | 0.4868–0.9743 | 0.7857 | 0.5241–0.9242 | 0.8469 | 0.7034–1 | 0.08 | <0.0001 | 6Ckine | <5415.84 | 0.8571 | 0.4868–0.9743 | 0.7857 | 0.5241–0.9242 | 0.7857 | 0.5666–1 | 0.13 | 0.0159 | I-TAC | <34.21 | 0.8333 | 0.4364–0.9699 | 0.9166 | 0.6461–0.9851 | 0.875 | 0.7198–1 | 0.09 | <0.0001 | MCP-3 | <24.49 | 1 | 0.5101–1 | 0.833 | 0.5519–0.9530 | 0.875 | 0.7222–1 | 0.09 | <0.0001 | MIF | <1483.82 | 0.8571 | 0.4868–0.9743 | 0.9166 | 0.6461–0.9851 | 0.8809 | 0.7385–1 | 0.08 | <0.0001 |
|
|