Research Article

Integrated Wearable System for Monitoring Heart Rate and Step during Physical Activity

Table 3

HR detection accuracy for one subject at 1.8 km/h.

Data no.Our DeviceGEErr.Acc. (%)Data No.Our DeviceGEErr.Acc. (%)

110010199169998199
210210498179896298
310410599189796199
4106106010019989999
5106104298209910099
6104101397211001000100
7101992982210098298
810098298239996397
910098298249795298
10999901002596960100
1199981992696960100
1298962982796960100
139796199289695199
149897199299694298
1599990100309694298

Average98.7