Research Article

Adaptive Step-Size Control in Simulation of Diffusive CVD Processes

Table 5

Numerical results for the P-controller for different spatial-steps with 𝐷 = 0 . 1 and 𝜆 = 1 . 0 as P-value for the controller.

Δ 𝑥 Δ 𝑡 e r r = | 𝑢 n u m , Δ 𝑥 , Δ 𝑡 𝑢 n u m , n e Δ 𝑥 , Δ 𝑡 | Convergence rate

0.10.10.0770073.2531
0.10.050.0161534.0077
0.10.0250.00200853.9447
0.10.01250.000260871.8276
0.10.006250.000146990

0.050.10.278732.8591
0.050.050.0768333.7481
0.050.0250.0114374.052
0.050.01250.0013793.7776
0.050.006250.000201110

0.0250.10.65642.4552
0.0250.050.239393.2449
0.0250.0250.0505054.008
0.0250.01250.00627813.9999
0.0250.006250.000784820

0.01250.11.042.1424
0.01250.050.47112.7173
0.01250.0250.143273.7251
0.01250.01250.0216684.0516
0.01250.006250.00261330

0.006250.11.20921.586
0.006250.050.805542.4179
0.006250.0250.301483.2179
0.006250.01250.0648034.005
0.006250.006250.00807260