Research Article

Blind Deconvolution of the Aortic Pressure Waveform Using the Malliavin Calculus

Table 2

The performance measure (SNRE) after added white Gaussian noise.

FIR-2FIR-4Malliavin calculus

Noise varianceSNRSNRESNRESNRE

138.199 db13.8976 db18.599 db24.927 db
1028.217 db13.479 db18.356 db23.443 db
7019.833 db12.748 db16.548 db18.808 db
10018.312 db12.441 db15.767 db17.664 db
30013.705 db10.851 db13.044 db13.768 db
50011.633 db9.7677 db11.466 db11.803 db
70010.309 db8.9428 db10.374 db10.523 db

The multichannel blind deconvolution (MBD) technique was applied by using the conventional method (FIR-2 model with two orders and FIR-4 model with 4 orders) and the proposed method (Malliavin calculus). We compared between these methods by using the performance measure SNRE (3.1) with the signal-to-noise ratio SNR at variant noise.