Abstract

The influence of switching frequency on the low-frequency oscillation in the voltage-controlled buck-boost converter is studied in this paper. Firstly, the mathematical model of this system is derived. And then, a glimpse at the influence of switching frequency on the low-frequency oscillation in this system by MATLAB/Simulink is given. The improved averaged model of the system is established, and the corresponding theoretical analysis is presented. It is found that the switching frequency has an important influence on the low-frequency oscillation in the system, that is, the low-frequency oscillation is easy to occur when the switching frequency is low. Finally, the effectiveness of the improved averaged model and the theoretical analysis are confirmed by circuit experiment.

1. Introduction

Unlike the PWM-controlled boost converter and the PWM-controlled buck converter, if the input voltage polarity of the PWM-controlled buck-boost converter is positive, its output voltage polarity will be negative [1], and accordingly this converter has been widely used in the condition that the negative output voltage is needed, such as the audio amplifier, the signal generator, or the data transmission interface. Therefore, the modeling, dynamical behaviors of the PWM-controlled buck-boost converter has been a focal topic research in recent years [2–11]. Especially, due to the fact that the PWM-controlled buck-boost converter is a strong nonlinear and nonautonomous system, the various kinds of nonlinear phenomena can be observed and the theoretical analysis of these nonlinear phenomena have also attracted much attention of researchers [3–11]. For example, Aroudi et al. studied the low-frequency oscillation and chaos in the voltage-controlled buck-boost converter by using the discrete model in 2000 [3]. Wu et al. studied the subharmonic and chaos in the current-controlled buck-boost converter by using the discrete model in 2002 [4, 5]. From the existing literatures, it is found that the main analysis model for investigating the nonlinear phenomenon in the PWM-controlled buck-boost converter is the discrete model [3–11]. However, this model is too complicated, especially for obtaining the solution of each state of the PWM-controlled buck-boost converter. Thus, it is difficult to use the discrete model to analyze and design the PWM-controlled buck-boost converter in the engineering applications. Especially, if the low-frequency region of the PWM-controlled buck-boost converter is only concerned, the discrete model is too redundant [12]. Additionally, the conventional averaged model is widely accepted to analyze and design this converter. Also, the conventional averaged model can be used to identify the occurrence of the low-frequency oscillation, and this point has been confirmed by Iu and Tse in [13]. However, the influence of the switching frequency on the low-frequency oscillation in the PWM-controlled buck-boost converter cannot be identified since there is no switching frequency parameter in its conventional averaged model. Therefore, it is necessary to explore other models to analyze the influence of the switching frequency on the low-frequency oscillation in the PWM-controlled buck-boost converter effectively and successfully.

In this paper, the influence of the switching frequency on the low-frequency oscillation in the voltage-controlled buck-boost converter is analyzed by establishing the improved averaged model. The rest of the paper is organized as follows. In Section 2, the circuit operation of the system and its mathematical model are given. In Section 3, a glimpse at the low-frequency oscillation in the voltage-controlled buck-boost converter from the MATLAB/Simulink is presented. And then, the improved averaged model of the system is established. In Section 5, theoretical analysis of the influence of switching frequency on the low-frequency oscillation in the system is given. In Section 6, some experimental results are given to confirm the effectiveness of the theoretical analysis. Finally, some concluding remarks and comments are given in Section 7.

2. Circuit Operation and Its Mathematical Model

The schematic of the voltage-controlled buck-boost converter is shown in Figure 1. Obviously, this system consists of two parts: the buck-boost converter and the voltage controller.Since the polarity of the output voltage is negative, the inverting amplifier (AM1) should be inserted in the voltage controller loop. Note that 𝑣0 is the output voltage of the voltage-controlled buck-boost converter, 𝑖𝐿 is the current through of the inductor L, 𝑣vf is the output voltage of the voltage compensator, d is the duty cycle, 𝑉in is the input voltage of the system, 𝑅 is the load resistor, 𝑉ref is the reference voltage, and 𝐶𝑣𝑓, 𝑅𝑣𝑓, 𝑅𝑣𝑖, and 𝑅𝑣𝑑 are the parameters of the voltage controller.

According to the circuit theory and the characteristic of each component, the mathematical model of the voltage-controlled buck-boost converter in the following three states can be derived.

The first state (𝑄 is on and 𝐷 is off):𝑑𝑖𝐿=𝑉𝑑𝑡in𝐿,𝑑𝑣0𝑣𝑑𝑡=−0,𝑅𝐶𝑑𝑣𝑣𝑓=𝑅𝑑𝑡𝑣𝑓2𝑅𝑣𝑖+𝑅𝑣𝑑−𝑣0+𝑣𝑅𝐶0𝐶𝑣𝑓𝑅𝑣𝑓+𝑉𝑟𝑒𝑓𝐶𝑣𝑓𝑅𝑣𝑑.(2.1)

The second state (𝑄 is off and 𝐷 is on):𝑑𝑖𝐿=𝑣𝑑𝑡0𝐿,𝑑𝑣0𝑖𝑑𝑡=−𝐿𝐶−𝑣0,𝑅𝐶𝑑𝑣𝑣𝑓=𝑅𝑑𝑡𝑣𝑓2𝑅𝑣𝑖+𝑅𝑣𝑑−𝑖𝐿𝐶−𝑣0+𝑣𝑅𝐶0𝐶𝑣𝑓𝑅𝑣𝑓+𝑉ref𝐶𝑣𝑓𝑅𝑣𝑑.(2.2)

The third state (𝑄 is off and 𝐷 is off)𝑖𝐿=0,𝑑𝑣0𝑣𝑑𝑡=−0,𝑅𝐶𝑑𝑣𝑣𝑓=𝑅𝑑𝑡𝑣𝑓2𝑅𝑣𝑖+𝑅𝑣𝑑−𝑣0+𝑣𝑅𝐶0𝐶𝑣𝑓𝑅𝑣𝑓+𝑉𝑟𝑒𝑓𝐶𝑣𝑓𝑅vd.(2.3)

Note that the switch 𝑄 is on or is off is determined by comparing the voltage 𝑣𝑣𝑓 with the ramp signal 𝑉ramp. If 𝑣𝑣𝑓>𝑉ramp, the switch 𝑄 is on. Otherwise, the switch 𝑄 is off. The 𝑉ramp is described as 𝑉ramp=𝑉𝐿+𝑉𝑈−𝑉𝐿𝑡𝑇mod1,(2.4) where VL is the lower threshold, VU is the upper threshold, Vm = VU − VL is the peak-to-peak value of the 𝑉ramp, and T is the switching period.

According to (2.1)–(2.4), the simulation model for the voltage-controlled buck-boost converter in the MATLAB/Simulink is established and shown in Figure 2.

The circuit parameters are chosen as 𝑉in = 12 V, L = 3 mH, C = 10 μF, R = 100 Ω, 𝑅vi=100 kΩ, 𝑅vd=20 kΩ, 𝑅𝑣𝑓=15 kΩ, 𝐶vf=1 μF, 𝑉ref=2 V, VL = 0 V, VU = 5 V. The dynamical behaviors of the voltage-controlled buck-boost converter under different switching frequency are investigated as follows. Note that the MATLAB/Simulink is an effective and convenient tool for calculating the numerical solution of the system and it has been widely used in power electronics, such as DC-DC converter [14, 15], AC-DC converter [15], and matrix converter [16]. Furthermore, when the simulation process is carried out, the solver is chosen as Ode23tb.

The simulation results for f = 20 kHz are shown in Figure 3. Figure 3(a) shows the time-domain waveform of the output voltage 𝑣0 and Figure 3(b) shows the time-domain waveform of the inductor current iL. It is obvious that the system is in stable operation and the peak value of inductor current is equal to 0.673 A, that is, 𝑖LM = 0.673 A.

The simulation results for f = 4 kHz is shown in Figure 4. It is obvious that the system is in unstable operation and the low-frequency oscillation occurs. Moreover, the peak value of inductor current is equal to 1.294 A, that is, 𝑖LM = 1.294 A, which is about to two times larger than the one for f = 20 kHz in stable operation. Obviously, the current stress of the switch and the diode is increased when the low-frequency oscillation occurs.

Also, in order to observe the influence of the switching frequency on the dynamical behaviors of the voltage-controlled buck-boost converter more clearly, the critical points of the occurrence of the low-frequency oscillation in the different parameter spaces from the MATLAB/Simulink are noted down and plotted in Figures 5 and 6. Figure 5 shows the results in the parameter space of the switching frequency f versus the resistor 𝑅vf and it is found that the low-frequency oscillation is easy to occur when the switching frequency f is low or the resistor 𝑅vf is high. Figure 6 shows the results in the parameter space of the switching frequency f versus the capacitor C and it is found that the low-frequency oscillation is easy to occur when the switching frequency f is low or the capacitor C is high.

From the above MATLAB/Simulink simulation results, the conclusion can be obtained that the switching frequency has an important influence on the occurrence of the low-frequency oscillation in the voltage-controlled buck-boost converter, that is, the low-frequency oscillation is easy to occur when the switching frequency is low, and accordingly it is necessary to explore the proper analysis model to investigate this influence in theoretic.

4. Theoretical Derivation

From Figures 3 and 4, one can see that the voltage-controlled buck-boost converter mainly operates in continuous conduction mode (CCM) operation, and accordingly only the CCM operation in the voltage-controlled buck-boost converter is considered in this paper. According to (2.1), (2.2), (2.4), and the average modeling method [13], the averaged model of the voltage-controlled buck-boost converter can be described directly as follows: 𝑑⟨𝑖𝐿⟩=𝑑𝑡⟨𝑣0⟩𝐿𝑉(1−⟨𝑑⟩)+in𝐿⟨𝑑⟩,𝑑⟨𝑣0⟩𝑑𝑡=−⟨𝑖𝐿⟩𝐶(1−⟨𝑑⟩)−⟨𝑣0⟩,𝑅𝐶𝑑⟨𝑣vf⟩=𝑅𝑑𝑡vf2𝑅vi+𝑅vd−⟨𝑖𝐿⟩𝐶(1−⟨𝑑⟩)−⟨𝑣0⟩+𝑅𝐶⟨𝑣0⟩𝐶vf𝑅vf+𝑉ref𝐶vf𝑅vd.(4.1) Note that ⟨𝑖𝐿⟩, ⟨𝑣0⟩, ⟨𝑣vf⟩, and ⟨𝑑⟩ are the average value of 𝑖𝐿, 𝑣0, 𝑣vf, and 𝑑, respectively. For the conventional averaged model, the duty cycle ⟨𝑑⟩ is determined by the value ⟨𝑣vf⟩/Vm and this point leads to the fact that there is no switching frequency parameter in the conventional averaged model. Therefore, this conventional averaged model cannot be used to analyze the influence of the switching frequency on the low-frequency oscillation in the voltage-controlled buck-boost converter.

In [17, 18], the duty cycle can be modeled by another method, which contains the switching frequency. For brevity to model the duty cycle ⟨𝑑⟩, (4.1) is rewritten as follows: ̇𝑥=𝐴0𝑥+𝑏0+𝐴1𝑥+𝑏1⟨𝑑⟩,(4.2) where, 𝑥=[⟨𝑖𝐿⟩,⟨𝑣0⟩,⟨𝑣vf⟩]T, T denotes the transpose of the matrix, 𝐴0 is the coefficient constant matrix of x, 𝐴1 is the coefficient constant matrix of 𝑥⟨𝑑⟩, 𝑏0 is constant matrix, and 𝑏1 is the coefficient constant matrix of ⟨𝑑⟩. Their expressions are derived as follows:𝐴0=⎡⎢⎢⎢⎢⎢⎢⎣01𝐿0−1𝐶−10−𝑅𝑅𝐶vf𝐶2𝑅vi+𝑅vd𝑅𝐶−𝑅vf𝐶vf2𝑅vi+𝑅vd𝐶vf0âŽ¤âŽ¥âŽ¥âŽ¥âŽ¥âŽ¥âŽ¥âŽ¦ğ‘…ğ¶,𝑏0=⎡⎢⎢⎢⎢⎣00𝑉ref𝐶vf𝑅vd⎤⎥⎥⎥⎥⎦,𝐴1=⎡⎢⎢⎢⎢⎢⎢⎣10−𝐿01𝐶𝑅00vf𝐶2𝑅vi+𝑅vd⎤⎥⎥⎥⎥⎥⎥⎦00,𝑏1=âŽ¡âŽ¢âŽ¢âŽ¢âŽ¢âŽ£ğ‘‰in𝐿00⎤⎥⎥⎥⎥⎦.(4.3)

According to [17, 18], the duty cycle ⟨𝑑⟩ can be described as follows:𝐾𝐾𝑥+𝐴2𝑓1𝑥+𝑏1⟨𝑑⟩−⟨𝑑⟩2=𝑉𝑚⟨𝑑⟩,(4.4) where K = [0,0,1].

By solving (4.4), the following equation can be obtained: ⟨𝑑⟩2+î‚µğ‘Žğ‘‰ğ‘šâŸ¨ğ‘–ğ¿âŸ©î‚¶âˆ’1âŸ¨ğ‘‘âŸ©âˆ’ğ‘ŽâŸ¨ğ‘£vf⟩⟨𝑖𝐿⟩=0,(4.5) where ğ‘Ž=2𝑓𝐶(2𝑅vi+𝑅vd)/𝑅vf.

Thus, the duty cycle ⟨𝑑⟩ is1⟨𝑑⟩=2âˆ’ğ‘Žğ‘‰ğ‘š2⟨𝑖𝐿⟩+12âˆ’ğ‘Žğ‘‰ğ‘š2⟨𝑖𝐿⟩2+ğ‘ŽâŸ¨ğ‘£vf⟩⟨𝑖𝐿⟩.(4.6) From (4.6), it is easy to see that the switching frequency is included apparently. Substituting (4.6) into (4.1), the improved averaged model of the system can be derived,𝑑⟨𝑖𝐿⟩=𝑑𝑡⟨𝑣0⟩+𝑉in−2ğ¿ğ‘Žğ‘‰ğ‘šî€·ğ‘‰in−⟨𝑣0⟩2𝐿⟨𝑖𝐿⟩+𝑉in−⟨𝑣0⟩𝐿𝑔⟨𝑖𝐿⟩,⟨𝑣vf⟩,𝑑⟨𝑣0⟩𝑑𝑡=−⟨𝑖𝐿⟩−2𝐶⟨𝑣0âŸ©âˆ’ğ‘…ğ¶ğ‘Žğ‘‰ğ‘š+2𝐶⟨𝑖𝐿⟩𝐶𝑔⟨𝑖𝐿⟩,⟨𝑣vf⟩,𝑑⟨𝑣vf⟩=𝑅𝑑𝑡vf2𝑅vi+𝑅vd−⟨𝑖𝐿⟩−2ğ¶ğ‘Žğ‘‰ğ‘š+2𝐶⟨𝑖𝐿⟩𝐶𝑔⟨𝑖𝐿⟩,⟨𝑣vf⟩+⟨𝑣0⟩𝐶vf𝑅vf−⟨𝑣0⟩+𝑉𝑅𝐶ref𝐶vf𝑅vd,(4.7) where𝑔⟨𝑖𝐿⟩,⟨𝑣vf⟩=12âˆ’ğ‘Žğ‘‰ğ‘š2⟨𝑖𝐿⟩2+ğ‘ŽâŸ¨ğ‘£vf⟩⟨𝑖𝐿⟩.(4.8) Since 𝑔(⟨𝑖𝐿⟩,⟨𝑣vf⟩) contains the parameter a, which contains the switching frequency f. Therefore, the improved averaged model, that is (4.7), depends on switching frequency f. Furthermore, the stability and the bifurcation type of (4.7) can be identified by observing the calculated eigenvalues of its Jacobian matrix at equilibrium point. The equilibrium point of (4.7) is as follows: ⟨𝑉0⟩=−2𝑅vi+𝑅vd𝑅vd𝑉ref,(4.9)⟨𝐼𝐿⟩=⟨𝑉0⟩2−𝑉in⟨𝑉0⟩𝑅𝑉in,(4.10)⟨𝑉vf⟩=âŸ¨ğ¼ğ¿âŸ©ğ‘Žî‚µ1+⟨𝑉0⟩𝑅⟨𝐼𝐿⟩2+î‚µğ‘‰ğ‘šâˆ’âŸ¨ğ¼ğ¿âŸ©ğ‘Žî‚¶î‚µ1+⟨𝑉0⟩𝑅⟨𝐼𝐿⟩,(4.11)⟨𝐷⟩=2𝑅vi+𝑅vd𝑉ref2𝑅vi+𝑅vd𝑉ref+𝑉in𝑅vd.(4.12) Note that ⟨𝐼𝐿⟩, ⟨𝑉0⟩, ⟨𝑉vf⟩, and ⟨𝐷⟩ are the steady state value of ⟨𝑖𝐿⟩, ⟨𝑣0⟩, ⟨𝑣vf⟩, and ⟨𝑑⟩, respectively. From (4.9)–(4.12), it is found that the steady state values ⟨𝑉0⟩, ⟨𝐼𝐿⟩, and ⟨𝐷⟩ do not depend on the switching frequency. However, the steady state value ⟨𝑉vf⟩ contains the switching frequency parameter, and it leads its value to be changed with the switching frequency changing.

Additionally, since the CCM operation in the voltage-controlled buck-boost converter is only concerned in this paper, the duty cycle constraint must be considered. According to [1], the condition for CCM operation is as follows:𝐿𝑓𝑅≥(1−⟨𝐷⟩)22.(4.13)

So, the duty cycle constraint is as follows:⟨𝐷⟩≥1−2𝐿𝑓𝑅.(4.14)

Furthermore, substituting (4.12) into (4.14), the switching frequency under CCM operation must satisfy the following inequality:𝑓≥𝑅𝑉in2𝑅vd2𝑉2𝐿in𝑅vd+2𝑅vi𝑉ref+𝑅vd𝑉ref2.(4.15)

Also, the Jacobian matrix Aga for (4.7) at its equilibrium point can be calculated as follows:ğ´ğ‘”ğ‘Ž=âŽ¡âŽ¢âŽ¢âŽ¢âŽ¢âŽ¢âŽ¢âŽ¢âŽ£î€·ğ‘‰in−⟨𝑉0⟩2𝑔1⟨𝐼𝐿⟩2+ğ‘Žğ‘‰ğ‘šî€¸2𝐿⟨𝐼𝐿⟩2−𝑔0𝐿+1+2ğ¿ğ‘Žğ‘‰ğ‘š2𝐿⟨𝐼𝐿⟩𝑉in−⟨𝑉0⟩𝑔2𝐿2𝑔0−1+2𝐶⟨𝐼𝐿⟩𝑔1𝐶−1𝑅𝐶⟨𝐼𝐿⟩𝑔2𝐶𝑅vf2𝑔0−1+2⟨𝐼𝐿⟩𝑔122𝑅vi+𝑅vd𝐶𝑅𝐶−𝐶vf𝑅vf𝑅𝐶2𝑅vi+𝑅vd𝐶vf𝑅vf⟨𝐼𝐿⟩𝑔22𝑅vi+𝑅vdî€¸ğ¶âŽ¤âŽ¥âŽ¥âŽ¥âŽ¥âŽ¥âŽ¥âŽ¥âŽ¦,(4.16) where𝑔0=𝑔⟨𝑖𝐿⟩,⟨𝑣vf⟩||⟨𝑖𝐿⟩=⟨𝐼𝐿⟩⟨𝑣vf⟩=⟨𝑉vf⟩=12âˆ’ğ‘Žğ‘‰ğ‘š2⟨𝐼𝐿⟩2+ğ‘ŽâŸ¨ğ‘‰vf⟩⟨𝐼𝐿⟩,𝑔(4.17)1=𝜕𝑔⟨𝑖𝐿⟩,⟨𝑣vf⟩𝜕⟨𝑖𝐿⟩||||⟨𝑖𝐿⟩=⟨𝐼𝐿⟩⟨𝑣vf⟩=⟨𝑉vf⟩=1212âˆ’ğ‘Žğ‘‰ğ‘š2⟨𝐼𝐿⟩2+ğ‘ŽâŸ¨ğ‘‰vf⟩⟨𝐼𝐿⟩−1/212âˆ’ğ‘Žğ‘‰ğ‘š2âŸ¨ğ¼ğ¿âŸ©î‚¶ğ‘Žğ‘‰ğ‘šâŸ¨ğ¼ğ¿âŸ©2âˆ’ğ‘ŽâŸ¨ğ‘‰vf⟩⟨𝐼𝐿⟩2,𝑔(4.18)2=𝜕𝑔⟨𝑖𝐿⟩,⟨𝑣vf⟩𝜕⟨𝑣vf⟩||||⟨𝑖𝐿⟩=⟨𝐼𝐿⟩⟨𝑣vf⟩=⟨𝑉vf⟩=ğ‘Ž2⟨𝐼𝐿⟩12âˆ’ğ‘Žğ‘‰ğ‘š2⟨𝐼𝐿⟩2+ğ‘ŽâŸ¨ğ‘‰vf⟩⟨𝐼𝐿⟩−1/2.(4.19)

According to [13], we know that if all the eigenvalues of Jacobian matrix lay in the left of the complex plane, the system is in stable operation. But, if there is a pair of complex eigenvalues across the imaginary axis to the right of the complex plane, it implies that Hopf bifurcation occurs in the system.

5. Influence Analysis

The circuit parameters are shown in Section 3. From (4.15), the switching frequency must be larger than 2.076 kHz to maintain the voltage-controlled buck-boost converter operating in CCM operation. Based on (4.16), the eigenvalues at the different switching frequency are calculated and noted down in Table 1. It is found that the system is in stable operation when f ≥ 14.8 kHz since all the eigenvalues lay in the left of the complex plane. Therefore, the voltage-controlled buck-boost converter must be in stable operation when f = 20 kHz, which has already been shown in Figure 3.

But, when the switching frequency is equal to 14.7 kHz, that is, f = 14.7 kHz, Hopf bifurcation occurs since there is a pair of complex eigenvalues across the imaginary axis to the right of the complex plane. Therefore, the system will operate in unstable operation. However, due to the topology of voltage-controlled buck-boost converter and the characteristic of the diode, the inductor current cannot also be enlarged on and on. Thus, the output voltage 𝑣0 cannot also be enlarged on and on. Finally, the low-frequency oscillation is formed. Therefore, the voltage-controlled buck-boost converter must be in low-frequency oscillation operation when f = 4 kHz, which has already been shown in Figure 4.

Additionally, by noting the bifurcation points at the different parameter spaces, the stable boundaries can also be obtained and shown in Figures 7 and 8. It is found that the results between the theoretical analysis and MATLAB/Simulink simulations are in good agreement with each other. So, it is effective to establish the improved averaged model to analyze the influence of switching frequency on the low-frequency oscillation in the voltage-controlled buck-boost converter.

6. Circuit Experiment

In order to confirm the influence of the switching frequency on the low-frequency oscillation in the voltage-controlled buck-boost converter and corresponding theoretical analysis, the circuit of the voltage-controlled buck-boost converter is designed and its full schematic diagram with detailed specifications is depicted in Figure 9. In our experiment, the voltage probe Agilent 10074C is used to detect the output voltage 𝑣0, the current probe Tektronix A622 is used to detect the inductor current iL and the digital oscilloscope Agilent 54622D is employed to capture the measured waveforms from the probes. Moreover, the switch 𝑄 is realized by IRFP460, the diode 𝐷 is realized by MUR1560, the amplifiers AM1 and AM2 are realized by LF356, and the comparator COM is realized by LM311. Additionally, the photocoupler TLP250 should be inserted for driving the switch IRFP460 since the ground of IRFP460 is floating. Additionally, in our experiment, it is also noted that (1)𝑉cc = 15 V, VD = 18 V, RT1 = 1.5 kΩ, RT2 = 268 Ω, RT3 = 510 Ω, RD = 510 Ω, and other circuit parameters’ value are shown in Section 3;(2)there are two types of ground in the TLP250. The first is 𝑁, which is the same as LM311 and LF356; however, the second is 𝑀, which is different from 𝑁 and it is essential to remain isolated.

As calculated in Section 5, the voltage-controlled buck-boost converter is in stable operation when f ≥ 14.8 kHz. Otherwise, the system will operate in low-frequency oscillation. Figure 10 shows the experimental results for f = 20 kHz, which is above the critical point. It is obvious that the system is in stable operation.

However, when we choose the switching frequency equal to 4 kHz, that is, f = 4 kHz, the voltage-controlled buck-boost converter really operates in low-frequency oscillation operation, which is shown in Figure 11. Furthermore, comparing the circuit experimental results (Figures 10 and 11) with the simulation results (Figures 3 and 4), it is found that they are in good agreement with each other qualitatively. The discrepancy is mainly caused by the fact that all the circuit components are considered as ideal in simulation.

7. Conclusion

Based on the established improved averaged model, the influence of switching frequency on the low-frequency oscillation in the voltage-controlled buck-boost converter is analyzed in this paper. The MATLAB/Simulink simulation results, theoretical results, and circuit experimental results described that the switching frequency has an important influence on the low-frequency oscillation in the voltage-controlled buck-boost converter, that is, the low-frequency oscillation is easy to occur when the switching frequency is low. Additionally, by comparing the conventional averaged model, the improved averaged model is an effective model to analyze the dynamical behaviors of the voltage-controlled buck-boost converter under different switching frequency.

Acknowledgments

This paper was supported by National Natural Science Foundation of China (Grant no. 51007068), Specialized Research Fund for the Doctoral Program of Higher Education (Grant no. 20100201120028), the Fundamental Research Funds for the Central Universities, and the State Key Laboratory of Electrical Insulation and Power Equipment (Grant no. EIPE10303).