Research Article
Modeling of Thermel Transport for GMAW
Table 1
Temperature readings (taken at the intervals of 10 sec up to 160 sec).
| Time (sec) | Temperature (at 1,1,0) on welded plates | Temperature (at 1,1.5,0) on welded plates | Temperature (at 1,2.5,0) on welded plates | Temperature (at 1,5,0) on welded plates |
| 10 | 30 | 30 | 30 | 30 | 20 | 230 | 183 | 97 | 30 | 30 | 260 | 190 | 100 | 30 | 40 | 275 | 303 | 115 | 30 | 50 | 291 | 235 | 121 | 43 | 60 | 310 | 240 | 129 | 54 | 70 | 330 | 250 | 140 | 53 | 80 | 320 | 254 | 145 | 55 | 90 | 313 | 247 | 151 | 58 | 100 | 289 | 242 | 155 | 58 | 110 | 270 | 235 | 147 | 60 | 120 | 250 | 230 | 140 | 63 | 130 | 235 | 215 | 135 | 63 | 140 | 225 | 202 | 128 | 65 | 150 | 217 | 197 | 123 | 65 | 160 | 205 | 187 | 116 | 68 |
|
|