Research Article

A Nonlinear Finite Element Method for Magnetoelectric Composite and the Study on the Influence of Interfacial Bonding

Figure 7

Numerical results on the field distributions of a three-layer laminated composite in poor bonding condition. (a) Shear stress , (b) normal stress , (c) electric field , (d) magnetization . The ineffective interfacial bonding results in a low stress and electric field the in ferroelectric material. The applied magnetic field is 630 Oe.
197940.fig.007