Research Article

The Influence of Shunt Active Power Filter on Stability and Performance in Considering Time-Delay

Table 3

The calculated value and fitted value for different values of , ( ,  mH).

/μs

Calculated value 22.98468.893114.73160.49206.19
Fitted value22.93568.805114.68160.55206.42