Research Article
Mathematical Modeling of Double-Skin Facade in Northern Area of China
Table 7
The contrast of the ratio of energy conversion when the building orientation is changed.
| Building orientation | The energy saving ratio of the DSF (%) | Reference to Low-e hollow glass curtain wall | Reference to concrete-perlites-85 |
| Northward | Heat energy saving rate | 8.0 | −9.0 | Air conditioning energy saving rate | 21.3 | −44.9 | Annual energy saving rate | 16.1 | −31.3 | Westward |
Heat energy saving rate |
9.5 |
−7.3 | Air conditioning energy saving rate | 28.2 | −36.8 | Annual energy saving rate | 21.3 | −23.0 | Southward |
Heat energy saving rate |
6.3 |
−10.2 | Air conditioning energy saving rate | 26.3 | −43.7 | Annual energy saving rate | 16.0 | −31.0 | Eastward |
Heat energy saving rate |
10.1 |
−6.2 | Air conditioning energy saving rate | 23.7 | −41.8 | Annual energy saving rate | 18.9 | −26.4 |
|
|