Research Article

Study of Intelligent Photovoltaic System Fault Diagnostic Scheme Based on Chaotic Signal Synchronization

Table 4

Actual fault diagnosis results.

QtyEDPF1EDPF2EDPF3EDPF4EDPF5EDPF6EDPF7EDPF8EDPF9Results

11.000−0.391−0.790−1.000−0.641−0.887−0.843−0.963−0.978PF1
21.000−0.391−0.790−1.000−0.641−0.887−0.843−0.963−0.978PF1
3−0.2221.000−0.476−1.000−0.103−0.719−0.610−0.908−0.945PF2
4−0.2221.000−0.476−1.000−0.103−0.719−0.610−0.907−0.945PF2
5−0.743−0.3911.000−1.000−0.042−0.1150.226−0.710−0.829PF3
6−0.743−0.3921.000−1.000−0.044−0.1160.224−0.710−0.829PF3
7−1.000−0.964−0.8901.000−0.931−0.787−0.858−0.581−0.448PF4
8−0.488−0.964−0.8901.000−0.931−0.787−0.858−0.581−0.448PF4
9−0.488−0.074−0.205−1.0001.000−0.573−0.408−0.860−0.917PF5
10−1.000−0.073−0.205−1.0001.000−0.573−0.408−0.860−0.917PF5
11−1.000−0.817−0.440−0.812−0.6531.000−0.280−0.517−0.638PF6
12−0.888−0.817−0.440−0.821−0.6531.000−0.280−0.517−0.638PF6
13−0.888−0.5720.145−1.000−0.272−0.0171.000−0.678−0.810PF7
14−1.000−0.5720.145−1.000−0.272−0.0171.000−0.678−0.810PF7
15−1.000−0.865−0.589−0.074−0.745−0.205−0.4711.0000.363PF8
16−1.000−0.865−0.589−0.074−0.745−0.205−0.4721.0000.363PF8
17−1.000−0.889−0.6620.015−0.791−0.346−0.5660.2851.000PF9
18−1.000−0.889−0.6620.015−0.791−0.346−0.5650.2861.000PF9