Research Article
Modeling, Parameters Identification, and Control of High Pressure Fuel Cell Back-Pressure Valve
Table 3
The performance of step response.
| Test type | Indicator | Position angle | Rise time (ms) | Regulation time (ms) | Overshoot (%) |
| Model simulation | 4–96% | <70 | <90 | <0.2 | 96–4% | <80 | <100 | <0.5 |