| | Before | Scheme 1 | Scheme 2 | Scheme 3 | Scheme 4 | Scheme 5 | Scheme 6 | Scheme 7 |
| Number of retrofit connections | 0 | 23 | 30 | 40 | 47 | 50 | 58 | 79 | Retrofit location | — | X1, X8-9 X23, X25 X28–29 X41, X45 X48, X51 X55, X62 X64, X67 X71, X73 X76-77 X81, X83 X86-87 | X2-3, X14 X18-19 X21, X24 X32, X34 X37, X40 X46, X47 X52 X55–59 X62, X67 X69 X70–72 X74, X78 X81 X86-87 | X3, X7, X11 X19–21 X23-24 X28 X30–34 X36–38 X44, X48 X51-X52 X54 X56-57 X64–66 X68, X71 X75 X77–80 X82–86 X90 | X2–4, X7 X11, X13 X17 X21-22 X25–27 X29–32 X34, X36 X38–40 X42-43 X47–51 X54–X56 X58, X60 X62, X65 X69 X71–73 X75-76 X78, X80 X83-84 X86–88 | X1, X4 X8–12 X14, X16 X20 X23-24 X26, X29 X32–37 X39, X42 X45–49 X53, X55 X57 X60-61 X63–65 X67, X69 X71-72 X74-75 X78 X80–82 X86–90 | X1, X3–6 X8–X10 X15, X18 X20, X22 X24–28 X31–X35X41– X44X46-47 X49– X52X54– X57X59- X60X63– X66X68–70 X72 X75– X77X79–84 X86 X88-89 | X1 X3–13 X15–21 X24–33 X35–37 X39–46 X49–62 X65–79 X81–90 | Initial retrofit cost (thousand dollars) | 0 | 460 | 600 | 800 | 940 | 1,000 | 1,160 | 1,580 | Lifetime seismic damage cost (thousand dollars) | 1,839 | 1,505 | 1,327 | 1,164 | 1,147 | 1,093 | 1,077 | 1,041 | Maximum interstory drift ratio (%) | 5.71 | 4.82 | 4.48 | 4.12 | 4.26 | 4.06 | 4.01 | 4.23 | Dissipated energy (kN·m) | 3,522.71 | 4,304.61 | 4,424.63 | 4,814.29 | 4,931.91 | 5,022.90 | 5,125.60 | 5,716.21 |
|
|