Research Article
Modeling Single-Phase Inverter and Its Decentralized Coordinated Control by Using Feedback Linearization
Table 1
System parameters.
| System quantities | Values |
| System frequency | 50 Hz | DC voltage | 600 V | Leader information | | Voltage | 1 p.u. | Line impedance | | = = = | 0.74 + | Load ratings | | | 10 KW and 6 kVAr | | 11.1 KW and 7 kVAr | | 10.1 KW and 5 kVAr | | 9.1 KW and 5 kVAr | | 11.1 KW and 5 kVAr | DG ratings | | DG-1 | 20 KW and 10 kVAr | DG-2 | 26.6 KW and 13.2 kVAr | DG-3 | 40 KW and 20 kVAr | Output inductances | | | 30 μH | | 22.53 μH | | 15 μH | Droop coefficients | | Active power-angle | | | 2 * 10−4 rad/w | | 1.5 * 10−4 rad/w | | 1 * 10−4 rad/w | Reactive power-voltage | | | 1 * 10−4 rad/VAr | | 0.75 * 10−4 rad/VAr | | 0.5 * 10−4 rad/VAr |
|
|