Abstract

A three-dimensional fluid-thermal-structural coupled analysis for a radial inflow micro gas turbine is conducted. First, a fluid-thermal coupled analysis of the flow and temperature fields of the nozzle passage and the blade passage is performed by using computational fluid dynamics (CFD). The flow and heat transfer characteristics of different sections are analyzed in detail. The thermal load and the aerodynamic load are then obtained from the temperature field and the pressure distribution. The stress distributions of the blade are finally studied by using computational solid mechanics (CSM) considering three cases of loads: thermal load, aerodynamics load combined with centrifugal load, and all the three types of loads. The detailed parameters of the flow, temperature, and the stress are obtained and analyzed. The numerical results obtained provide a useful knowledge base for further exploration of radial gas turbine design.

1. Introduction

Micro gas turbines are energy generators whose capacity ranges from 15 kW to 300 kW. In recent years, micro gas turbines have been widely studied and used because of their typical advantages such as variable speed, high speed operation, compact size, simple operability, easy installation, and low maintenance. In 2003, Johnston et al. [1] built and tested a microscale, high-speed compressor impeller (12 mm diameter; 800,000 rpm) for feasibility in regard to aerodynamic performance. The results from a CFD code agreed with measured data very well, suggesting that that design method combined with CFD techniques could be used to develop rotors for a microscale, gas turbine engine. In the work by Ribaud [2], a thermodynamic model was developed and applied to study heat transfer characteristic in an ultra-micro turbine at different situations. McDonell et al. [3] studied the performance of a micro gas turbine at various conditions, and optimum operating parameters were obtained. Further, Rodgers [4] investigated flow characteristics and aerodynamic performance of a micro gas turbine. It was reported that the main factors that affected the gas turbine performance were speed ratio, rotor blade tip clearance, and outlet flow angle. Onishi et al. [5] used a full three-dimensional Navier-Stokes solver to design and study aerothermodynamics of a micro gas turbine. Losses due to the heat transfer to walls and skin friction were estimated, and the effects of turbine exhaust geometry and the number of blades on turbine performance were also studied. Fu et al. [6] performed numerical investigations on the aerothermodynamic design, geometrical design, and overall performance prediction of a millimeter-scale radial turbine.

In the design of micro gas turbines, the heat-flow coupling method is widely used to obtain the temperature distribution of the gas turbine blades. In the investigation by Bohn and Kusterer [7], a cooling configuration with cooling fluid ejection through two rows of holes at leading edge was numerically studied by applying a heat-flow coupling method. Bohn and Heuer [8, 9] presented a conjugated aerodynamic and thermal numerical investigation of a convection-cooled, high-pressure turbine nozzle guide vane. A heat-flow coupling simulation was conducted for the C3X and MarkII blade. Other applications of heat-flow coupling method for the investigation of the heat transfer in micro gas turbine can also be found in the works of Bohn et al. [10, 11]. Hill et al. [12] presented a model which takes into account the formation of oscillation notches on a steel surface. The authors presented a model to couple the flux flow with the heat transfer. Besides, equations correlating the temperature field in the steel and flux with the geometry of the lubricating layer are derived. Further, Wu et al. [13] developed a single domain enthalpy control volume method to solve coupled fluid flow and heat transfer with solidification problem arising from the continuous casting process. They found that their numerical method was robust in capturing the rapid change of temperature in the solidification region. The rapid change of fluid velocity near the solid-fluid interface could also be obtained.

The stress analysis for a micro gas turbine is usually necessary for safety and reliability. The load on a radial turbine consists of thermal load resulting from the temperature gradient, centrifugal load caused by the turbine rotation, and aerodynamic load. Thus, in stress analysis of thermal stress, centrifugal stress and the stress caused by the aerodynamic force should be analyzed. Ho and Paull [14] described a method to implement aerodynamic heating models into a finite element code for thermal-structural and thermal-structural-vibrational analyses of a hypersonic engine. A combined effect of varying dynamic pressure and thermal loads was considered, and thermal-structural-vibrational response of an engine was studied. Shen et al. [15] conducted a fluid-thermal-structure coupled analysis and an optimization of a turbine mortise/disc. In their work, a complete multidisciplinary method containing fluid-thermal-structure of the mortise/disc was formed, taking influence of the fluid flow and heat transfer into account. Recently, Krishnakanth et al. [16] carried out finite element analysis for the structural and thermal analysis of gas turbine rotor blades. They found that the temperature had a notable effect on the overall stresses in the turbine blades. Other relevant works involving multidisciplinary analysis and optimization design of gas turbines can be found in [1721].

In this paper, the ANSYS 11.0 software is used for a fluid-thermal-structural coupling analysis of the micro gas turbine. At first, a heat-flow coupling analysis is conducted to obtain temperature distribution of a gas turbine blade and the aerodynamic force on the turbine blade. After obtaining the temperature distribution of the micro gas turbine, a stress analysis is then conducted considering three cases of loads: thermal load, aerodynamics load combined with centrifugal load, and all the three types of loads. Unlike the previous studies, this paper systematically studied the three cases to ensure the safety and reliability of the gas turbines.

2. Heat-Flow Coupling Method

2.1. Numerical Method

Usually the heat-flow coupling method is used to obtain temperature distribution of gas turbine blades. This method is much better than the decoupling simulation method because it can obtain more accurate temperature field by solving the heat convection equation in the fluid domain and the heat conduction equation in the solid domain simultaneously. In this method, a Navier-Stokes (NS) solver for the fluid flow and a finite element analysis (FEA) for the heat conduction in the solid are used. Figure 1 shows the data exchange of the coupling method at an interface. For the fluid-thermal-structural coupled analysis of the gas turbine, the imposed aerodynamic force and temperature distribution on the turbine are obtained from the heat-flow coupling analysis. In the fluid-thermal-structural coupled analysis, the FEA mesh used for stress analysis is the same as the mesh used for the heat-flow coupling analysis. As a result, the aerodynamic force and temperature distribution on the turbine obtained from the heat-flow coupling analysis can be directly imposed on the mesh that is used for fluid-thermal-structural coupled analysis.

The convective heat transfer equation is used at the interface for the data exchange of the coupling method, and it can be expressed as follows: where is the heat flux at the interface obtained by the N-S solver, is the convective heat transfer coefficient, is the wall temperature obtained by the FEA solver, and is the flow temperature obtained by the N-S solver. The interpolation method used for the data exchange of the coupling method is expressed as follows: where is the temperature at the center of the element mesh in the solid domain, is the temperature at the center of the element mesh in the fluid domain, is the length of the centerline of the two elements in the solid domain, and is the length of the centerline of the two elements in the fluid domain.

The commercially available CFD package CFX is used for the heat-flow coupling analysis of the micro gas turbine. In the analysis of aerodynamic performance and heat transfer characteristics, the numerical interpolation method is used for the energy coupling at the interface between the flow and solid domains. To obtain the stress distribution of the turbine, a thermostructural analysis is carried out with the aerodynamic parameters and heat transfer parameters applied using the finite element package ANSYS. The nonadiabatic flow is calculated by solving the 3D steady Navier-Stokes equations, which are expressed in detail as follows.Continuity equation is given as follows: Momentum conservation equation is given as follows: Energy conservation equation is given as follows:

where , , and are defined as follows: Hydrostatic equation in the solid domain is given as follows:

where is the volume force, is the surface force, and is the thermal stress caused by the variation in temperature. In this paper, the thermal load caused by the initial strain is also considered, which is usually ignored in the previous studies.

2.2. Geometry Model of the Turbine

The geometry of the micro radial inflow gas turbine is shown in Figure 2, and the flow domain is shown in Figure 3. Table 1 shows the structural parameters of the stator cascade, and the rotor blade passage is shown in Figure 4.

2.3. Mesh Generation

The commercially available ANSYS ICEM is used for the structured mesh generation. Figure 5 shows the mesh for a single stator blade. An O-topology mesh is applied to model the blade, and the mesh around the blade is refined. For a single stator blade, there are totally 6.9 × 104 and 2.0 × 104 cells in the fluid domain and the solid domain, respectively.

Figure 6 shows the mesh for a single rotor blade. A refined O-topology mesh is also applied around the rotor blade. Considering the tip clearance effects on the flow, the mesh in the tip clearance is also refined. Finally, there are 1.84 × 105 nodes in the flow domain for a single rotor blade. The mesh for the rotor blade in the solid domain is shown in Figure 7. As observed, the mesh at the blade root and the leading and trailing edge of the blade is refined for accurate simulation results. There are 4.1 × 104 nodes in the solid domain for a single rotor blade. Totally, there are 5.19 × 106 nodes in the computational domain.

2.4. Boundary Conditions and Validation Study

In the heat-flow coupling analysis of the micro gas turbine, four computational domains are used: flow domain of the stator blade, solid domain of the stator blade, flow domain of the rotor blade, and solid domain of the rotor blade. The inlet total temperature and pressure are 930°C and 342037 Pa, respectively, and the outlet pressure is 109920 Pa. Computations were carried out at a design condition of 800,000 rpm and at the test condition of 60000 rpm.

In the simulation, the general grid interface (GGI) connection is used for the interface between the flow domain and the solid domain, and the general connection method is used for the interface between the outlet of the stator blade flow domain and the inlet of the rotor blade flow domain. The solid boundaries are assumed to be adiabatic, and a no-slip boundary condition is applied along the solid boundaries. Only conduction and convection are taken into account. Radiation is neglected since differences in surface temperatures are small. The SST turbulence model with γ-Reθ transition model developed by Menter [22] is used in all the computations.

The heat-flow coupling method used in this paper has been validated by simulating the experimental study of surface heat transfer distributions of a turbine vane with film cooling by Hylton et al. [23, 24]. The simulation is conducted for the C3X turbine vane at the experimental condition of Test 5422. Figure 8 shows the dimensionless pressure distribution along the vane surface. As observed, our computational result agrees with the experimental results by Hylton et al. [23, 24] very well.

2.5. Results and Discussions

In this section, the flow field and temperature field in the blade passage are analyzed by heat-flow coupling method. The flow pattern and heat transfer characteristics are investigated. Figure 9 shows the velocity distribution and streamline in the middle section of the stator blade. It can be observed that the flow velocity at the inlet is quite uniform, and a notable change in flow velocity distribution occurs in the blade passage. After entering the blade passage, the flow direction changes and a stagnation zone can be observed at the pressure surface around the leading edge. The stagnation point is located at 10% chord from the leading edge. The flow area decreases along the blade passage, leading to an increase in the flow velocity. A maximum flow velocity of 500 m/s is observed at 40% chord from the leading edge. The flow velocity at the outlet of the stator blade is relatively high and uniform.

Figure 10 shows the pressure distribution in the middle section of the stator blade. A significant increase in pressure is observed at the pressure surface around the leading edge. The pressure gradient at the suction surface around the leading edge is relatively high, and the pressure decreases from about 320000 Pa to 220000 Pa. The minimum pressure is observed at 40% chord from the leading edge.

The blade profile of the turbine varies along the blade height. Three typical sections along the blade height are chosen for a better investigation of the flow pattern and heat transfer characteristics. To study the flow pattern around the blade, the velocity distribution and local streamline for the sections of 10%, 50%, and 90% blade height are shown in Figure 11. In the section of 10% blade height, flow separation around the blade is observed, and the stagnation point is located around the leading edge of the pressure surface, where a vortex can be observed. The decrease in pressure and increase in flow velocity result in a maximum velocity of 350 m/s around the trailing edge, where notable velocity gradient can be observed. At the suction side, the flow is q steady, and the variation in the flow velocity is relatively smooth. No flow separation can be found at the suction side except for the counter-rotating vortex pair at the trailing edge. In the section of 50% blade height, a higher maximum flow velocity of 420 m/s is observed, and there is no vortex at the leading and trailing edge of the blade. In the section of 90% blade height, the tip clearance has notable effects on the flow, leading to the inhomogeneous flow around the blade.

Figure 12 shows the pressure distribution for the section of 10%, 50%, and 90% blade height. A relatively high pressure gradient is observed at the inlet. In the section of 10% and 50% blade height and in the section of 90% blade height, the distribution of the isopiestic line is quite different. At the leading edge, a significant pressure gradient occurs, and the flow state changes dramatically. This can be attributed to the tip leakage flow caused by the tip casing scraping flow and pressure difference in the tip clearance [25].

The dimensionless pressure and temperature are used to analyze the flow field. The dimensionless pressure and temperature are the ratios of the pressure and temperature of the rotor blade surface to the inlet pressure and temperature of the rotor stage, respectively. Figure 13 shows the dimensionless pressure distribution on the turbine blade. A maximum dimensionless pressure of 0.62 can be observed at the leading edge of the pressure surface. The surface pressure decreases in the flow direction. The dimensionless pressure at the pressure surface is basically higher than 0.42, and the dimensionless pressure at the suction surface is relatively lower with a maximum value of 0.4 at the inlet. Besides, the pressure gradient at the pressure surface is relatively high, and the minimum dimensionless pressure occurs at the trailing edge. At the trailing edge of the suction side, a notable pressure gradient in the radial direction is observed, resulting from the increase in blade height and blade twist.

The analysis of blade temperature is very important because it has a notable effect on the thermal stress calculation and blade life prediction. Figure 14 shows the dimensionless temperature distribution on the turbine blade. As observed, the dimensionless temperature at the inlet is relatively high because of the convection heat transfer between the blade and hot gas. In the blade passage, the gas does work by expansion, leading to a decrease in the pressure and temperature along the blade passage. A maximum dimensionless temperature of 0.89 is observed at the inlet, and the minimum dimensionless temperature occurs at the blade root around the trailing edge.

3. Coupled Fluid-Thermal-Structural Analysis

3.1. Boundary Conditions and Solution Methods

The commercially available FEM package ANSYS 11.0 is used for the stress analysis of the rotor blade, based on the heat-flow coupling analysis above. The FEM mesh used for stress analysis is obtained from the results of the heat-flow coupling analysis; thus, it is the same as the mesh used for heat-flow coupling analysis, as shown in Figure 15.

The load on the radial turbine in this paper consists of thermal load resulting from the temperature gradient in the turbine, centrifugal load caused by the centrifugal force, and aerodynamic load.

3.2. Results and Discussions

Three cases are considered to analyze the effect of different loads on the overall stress of the turbine, as shown in Table 2. For strength analysis, the dimensionless equivalent stress is used, which is the ratio of the equivalent stress to the maximum equivalent stress in the turbine. Figure 16 shows the dimensionless equivalent stress distribution on the rotor blade. The dimensionless thermal stress distribution for Case 1 is shown in Figure 16(a). A maximum thermal stress of 133 MPa occurs at the blade tip of 30% chord from the leading edge. As observed, a stress concentration region occurs at the blade root of 60% chord from the leading edge. This is consistent with the high temperature gradient in this region obtained in the heat-flow coupling analysis. Figure 16(b) shows the dimensionless equivalent stress distribution for Case 2. A maximum equivalent stress of 347 MPa occurs at the blade root of 40% chord from the leading edge. Besides, the dimensionless equivalent stress decreases with the increasing blade height. The equivalent stress distribution for Case 3 is shown in Figure 16(c). As observed, the stress distribution is quite similar with that in Case 2, and two stress concentration regions occur on the blade. One is located at the blade tip of 30% chord from the leading edge, and the other is located at the blade root of 40% chord from the leading edge. The yield strength of the turbine material is higher than 700 MPa, and the maximum equivalent stress is 406 MPa, indicating that the micro gas turbine is safe and reliable in operation.

4. Conclusions

In this paper, the three-dimensional flow pattern and heat transfer characteristics in a micro gas turbine are studied by using the heat-flow coupling method. The stress distribution of the turbine is also investigated based on the results of the heat-flow coupling analysis. The main conclusions are summarized as follows.(1)The flow in the stator blade passage is smooth. For the rotor blade passage, a vortex occurs at the leading edge of the pressure surface, and a counter-rotating vortex pair occurs at the trailing edge of the blade. The flow is much smoother at a higher blade height.(2)In the section of 90% blade height, the tip clearance has notable effects on the flow, leading to the inhomogeneous flow around the blade tip. The variation in the impeller temperature is relatively smooth, the maximum temperature occurs at the inlet, and the minimum temperature occurs at the blade root around the trailing edge.(3)A maximum thermal stress of 113 MPa is obtained when only considering the thermal load, indicating that the effects of thermal stress cannot be neglected. When considering the effect of centrifugal load and aerodynamic load, a maximum equivalent stress of 347 MPa is obtained. With a consideration of thermal load, centrifugal load, and aerodynamic load, a maximum equivalent stress of 406 MPa is obtained.

Conflict of Interests

The authors declare that there is no conflict of interests regarding the publication of this paper.