Table of Contents Author Guidelines Submit a Manuscript
Mathematical Problems in Engineering
Volume 2014 (2014), Article ID 796812, 8 pages
http://dx.doi.org/10.1155/2014/796812
Research Article

An Optimal Method for Diffusion Parameters of Nonlinear Diffusion Problem of Drug Releasing in 2D-Disc Device by Separate Variable Method

1State Key Laboratory of Simulation and Regulation of Water Cycle in River Basin, Beijing 100038, China
2College of Highway Engineering, Changsha University of Science and Technology, Hunan, 410004, China
3College of Computer, Central South University of Forestry and Technology, Changsha 410004, China

Received 14 November 2013; Revised 16 February 2014; Accepted 16 February 2014; Published 23 March 2014

Academic Editor: Vassilios C. Loukopoulos

Copyright © 2014 Youyun Li et al. This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

Linked References

  1. J. Siepmann, A. Ainaoui, J. M. Vergnaud, and R. Bodmeier, “Calculation of the dimensions of drug-polymer devices based on diffusion parameters,” Journal of Pharmaceutical Sciences, vol. 87, no. 7, pp. 827–832, 1998. View at Publisher · View at Google Scholar · View at Scopus
  2. G. J. Crawford, C. R. Hicks, X. Lou et al., “The Chirila Keratoprosthesis: phase I human clinical trial,” Ophthalmology, vol. 109, no. 5, pp. 883–889, 2002. View at Publisher · View at Google Scholar · View at Scopus
  3. S. Wang and X. Lou, “Novel mathematicsl models for extracting effective drug diffusivity of porous PHEMA hydrogels: from a planar matrix into a finite external volume,” in Proceeding of the ICEAM, Changsha, China, May 2011.
  4. M. Grassi and G. Grassi, “Mathematical modelling and controlled drug delivery: matrix systems,” Current Drug Delivery, vol. 2, no. 1, pp. 97–116, 2005. View at Publisher · View at Google Scholar · View at Scopus
  5. X. Lou, S. Vijayasekaran, R. Sugiharti, and T. Robertson, “Morphological and topographic effects on calcification tendency of pHEMA hydrogels,” Biomaterials, vol. 26, no. 29, pp. 5808–5871, 2005. View at Google Scholar · View at Scopus
  6. M. B. Mellott, K. Searcy, and M. V. Pishko, “Release of protein from highly cross-linked hydrogels of poly(ethylene glycol) diacrylate fabricated by UV polymerization,” Biomaterials, vol. 22, no. 9, pp. 929–941, 2001. View at Publisher · View at Google Scholar · View at Scopus
  7. J. Zhu and Q. Zeng, “A mathematical theoretical frame for control of air pollution,” Science in China. Series D, vol. 32, pp. 864–870, 2002. View at Google Scholar
  8. P. E. Price Jr., S. Wang, and I. H. Romdhane, “Extracting effective diffusion parameters from drying experiments,” AIChE Journal, vol. 43, no. 8, pp. 1925–1934, 1997. View at Google Scholar · View at Scopus
  9. Y. Li, Z. Xiang, and S. Wang, “Identifying time-dependent drug diffusion parameters in the Cylindrical tube by the finite difference method,” in Proceeding of the ICEAM, Changsha, China, May 2011.
  10. D. Parra-Guevara and Y. N. Skiba, “Elements of the mathematical modeling in the control of pollutants emissions,” Ecological Modelling, vol. 167, no. 3, pp. 263–275, 2003. View at Publisher · View at Google Scholar · View at Scopus
  11. J. C. Fu, C. Hagemeir, and D. L. Moyer, “An unified mathematical model for diffusion from drug polymer composite tablets,” Journal of Biomedical Materials Research, vol. 10, no. 5, pp. 743–758, 1976. View at Google Scholar · View at Scopus
  12. A. Hukka, “The effective diffusion coefficient and mass transfer coefficient of nordic softwoods as calculated from direct drying experiments,” Holzforschung, vol. 53, no. 5, pp. 534–540, 1999. View at Google Scholar · View at Scopus
  13. C. R. Hicks, G. J. Crawford, X. Lou, D. T. Tan et al., “Cornea replacement using a synthetic hydrogel cornea, AlphaCor: device, preliminary outcomes and complications,” Eye, vol. 17, pp. 385–392, 2003. View at Publisher · View at Google Scholar
  14. Y. Li, Z. Xiang, X. Xiang, and S. Wang, “A computer algorithm for optimizing to extract effective diffusion coefficients of drug delivery from cylinders,” Information Technology Journal, vol. 9, no. 8, pp. 1647–1652, 2010. View at Google Scholar · View at Scopus