Research Article

Fault Diagnosis of Oil-Immersed Transformers Using Self-Organization Antibody Network and Immune Operator

Table 3

Sample distribution and memory antibodies.

Fault typeSample amountTraining sample amountInitial antibody amountMemory antibody amount

T143261116
T264391421
T386521725
D167411319
D25232914
PD38231216

Total35021376111