Research Article

A Computational Model to Assess Poststenting Wall Stresses Dependence on Plaque Structure and Stenosis Severity in Coronary Artery

Table 2

Pressure values, lumen diameter (LD), and fibrous cap thickness (FCT) for 40%, 60%, and 80% stenosed arteries under two separate expansion schemes. In the left side, the pressure values required to open the stenosed artery to the healthy lumen diameter are given. In the right side, the lumen diameter of stenosed arteries is given when the arteries are expanded with a fixed pressure of 100 mmHg.

Degree of stenosis (%)Displaced to healthy lumen diameter
of 2.68 mm
Displaced under fixed pressure
of 100 mmHg
ThinMediumThickThinMediumThick
PressureFCTPressureFCTPressureFCTLDFCTLDFCTLDFCT

401340.0581400.1151460.1732.590.0582.580.1202.570.181
604500.0635100.1265500.1952.080.0862.060.1752.050.264
8012550.02716200.06918300.1321.450.1131.430.2291.410.348