Research Article
One-Step-Ahead Predictive Control for Hydroturbine Governor
Table 1
Transmission coefficients as a function of gate opening.
| Operating point number | Gate opening % | | | | | |
| 1 | 43.74 | 2.867 | 0.526 | −0.353 | 1.674 | 0.232 | 2 | 47.52 | 2.562 | 0.679 | −0.455 | 1.541 | 0.262 | 3 | 51.26 | 2.278 | 0.814 | −0.545 | 1.416 | 0.290 | 4 | 55 | 2.016 | 0.934 | −0.626 | 1.300 | 0.315 | 5 | 58.74 | 1.766 | 1.039 | −0.696 | 1.191 | 0.338 | 6 | 62.52 | 1.654 | 1.132 | −0.759 | 1.090 | 0.360 | 7 | 66.26 | 1.333 | 1.212 | −0.813 | 0.997 | 0.380 | 8 | 70 | 1.146 | 1.281 | −0.859 | 0.913 | 0.397 | 9 | 73.74 | 0.974 | 1.340 | −0.898 | 0.837 | 0.414 | 10 | 77.52 | 0.822 | 1.391 | −0.932 | 0.768 | 0.429 | 11 | 81.26 | 0.691 | 1.433 | −0.961 | 0.708 | 0.443 | 12 | 85 | 0.578 | 1.468 | −0.984 | 0.655 | 0.455 | 13 | 88.74 | 0.484 | 1.498 | −1.000 | 0.611 | 0.467 | 14 | 92.52 | 0.409 | 1.523 | −1.020 | 0.574 | 0.478 | 15 | 96.26 | 0.353 | 1.544 | −1.030 | 0.546 | 0.489 | 16 | 100 | 0.317 | 1.563 | −1.047 | 0.526 | 0.499 |
|
|