Research Article

Experimental and Numerical Study on the Resistance Performance of an Axial Flow Cyclone Separator

Table 6

Pressure drop of axial flow cyclone separator with inlet velocity of 10 m/s.

Number1234567

Ambient pressure (Pa)815009900015000015150020150010150099000
Ambient temperature (K)253253253253253273283
Pressure drop by CFD (Pa)418.82508.99769.38778.321032.45484.32455.08
Pressure drop by (8) (Pa)418.69508.60770.60778.311035.18483.24454.68
Relative error (%)−0.03−0.080.16−0.0020.26−0.22−0.09

Number891011121314

Ambient pressure (Pa)8150099000101325101500101325202750303975
Ambient temperature (K)300300300300400400400
Pressure drop by CFD (Pa)354.38429.60438.99439.96330.84660.64989.41
Pressure drop by (8) (Pa)353.10428.92X439.75329.24658.81987.73
Relative error (%)−0.36−0.09X−0.05−0.48−0.28−0.17