Research Article
Sensitivity Analysis of Temperature Control Parameters and Study of the Simultaneous Cooling Zone during Dam Construction in High-Altitude Regions
Table 8
Effect of the amount and height of the simultaneous cooling zone on temperature stress.
|
Case |
Height of the simultaneous cooling zone (m) |
Basic restrain zone simultaneous cooling measure |
Maximum temperature at the high restraint zone (°C) | Maximum tensile stress in the high restraint zone | (Mpa) | Elevation (m) | Safety coefficient
|
| Case 1 | 18 | 18 m below the 3,300 m elevation Simultaneous cooling during the middle and second stages | 24.15 | 1.65 | 3304.5 | 1.53 |
| Case 2 | 18 + 27 | On the basis of case 1, adding 27 m above the 3,300 m elevation | 24.15 | 1.40 | 3304.5 | 1.81 |
|
|
Note: (1) 18 + 27 means that the first simultaneous cooling zone is 18 m, and the second one is 27 m.
|