Research Article
Time Reversal Reconstruction Algorithm Based on PSO Optimized SVM Interpolation for Photoacoustic Imaging
Table 2
Reconstruction performance of different interpolation methods on time reversal algorithm (15% noise).
| Time reversal method | MSE (30) | PSNR (30) | TIME (30)/s | MSE (50) | PSNR (50) | TIME (50)/s |
| Conventional | 0.3230 | 1.7000 | 0 | 0.1913 | 3.9749 | 0 | Linear interpolation | 0.1384 | 5.3813 | 0.1094 | 0.0522 | 9.6185 | 0.1090 | Cubic convolution interpolation | 0.1336 | 5.5324 | 0.0101 | 0.0511 | 9.7049 | 0.0105 | Cubic spline interpolation | 0.1236 | 5.8695 | 0.0121 | 0.0498 | 9.8194 | 0.0123 | PSO optimized SVM interpolation | 0.0776 | 7.8775 | 0.4978 | 0.0255 | 12.7833 | 0.4979 |
|
|