Research Article

Numerical Algorithms for the Analysis of Initial Configuration in a Railway Catenary Structure and Its Code Implementation: A Software Tool CALPE

Table 4

Length of the droppers and comparison results, reference [4], without presage.

ā€‰ Dropper 1 Dropper 2 Dropper 3 Dropper 4 Dropper 5
(m)(m)(m)(m)(m)

Cho et al. [4], method 1 0.8760.7400.6370.5690.535
Cho et al. [4], method 2 0.8750.7380.6360.5670.533
Present work, method 1 0.876060.739290.636710.56833 0.53414
Present work, method 2 0.876070.739300.636730.568340.53415