Research Article

Numerical Algorithms for the Analysis of Initial Configuration in a Railway Catenary Structure and Its Code Implementation: A Software Tool CALPE

Table 5

Length of the droppers and comparison results, reference [4], with presage.

ā€‰ Dropper 1 Dropper 2 Dropper 3 Dropper 4 Dropper 5
ā€‰ (m) (m) (m) (m) (m)

Cho et al. [4], method 1 0.876 0.779 0.706 0.658 0.633
Cho et al. [4], method 2 0.875 0.778 0.705 0.657 0.633
Present work, method 1 0.87606 0.77881 0.70587 0.65725 0.63294
Present work, method 2 0.87607 0.77882 0.70588 0.65725 0.63295