Research Article

Field Application of Cable Tension Estimation Technique Using the h-SI Method

Table 10

Cable tension force estimated from existing methods and the h-SI method.

MethodsEstimated cable tension (MN)
F1F2F3F4

Taut string theory5.586
(−1.000)
5.532
(−1.401)
5.226
(−1.547)
5.253
(1.152)
Triantafyllou and Grinfogel [16]5.578
(−1.147)
5.534
(−1.372)
5.226
(−1.545)
5.253
(1.152)
Linear regression method5.571
(−1.276)
5.518
(−1.650)
5.214
(−1.773)
5.267
(1.419)
Shimada [2]5.549
(−1.653)
5.486
(−2.233)
5.196
(−2.110)
5.204
(0.206)
Sensitivity updating algorithm 5.583
(−1.058)
5.525
(−1.533)
5.233
(−1.413)
5.275
(1.579)
Microgenetic algorithm (-GA)5.592
(−0.899)
5.514
(−1.729)
5.250
(−1.093)
5.287
(1.810)
This study (h-GA + SUA)5.583
(−1.058)
5.525
(−1.533)
5.233
(−1.413)
5.272
(1.521)

Static jacking force ()5.6435.6115.3085.193

( ): identification error (%).