Research Article

Fractional-Derivative Maxwell Kelvin Model for “5+4” Viscoelastic Damping Wall Subjected to Large Deformation

Table 5

Comparison of the areas of the experimental and theoretical hysteresis loops.

Frequency (Hz)Theoretical value (kN·mm)Experimental value (kN·mm)

0.5 (225%)227924135.6%
1.5 (225%)210422496.9%
0.5 (300%)284928260.8%
1.5 (300%)244525403.7%
0.5 (450%)524053942.9%
1.5 (450%)442745302.3%