Research Article

Compact Wide Frequency Range Fractional-Order Models of Human Body Impedance against Contact Currents

Table 1

Average and standard deviation of circuit models parameters and LSE from NLSF parameters for models one, two, and three to represent human impedance data.

Model LSE (F sec) (F sec)

One Avg. 517.5 k 64.13 μ
Std. Dev. 0.183 m 271.3 k 0.307 n 0.442 μ

Two Avg. 11.8 n 19.0 μ
Std. Dev.  m 7.9 n 2.1 μ

Three Avg. 3.72 k 4.36 μ 20.0 n
Std. Dev.  k 2.42 k 2.2 μ 15.3 n