Research Article
Effect of Element Size in Random Finite Element Analysis for Effective Young’s Modulus
Table 2
Critical
ratios and critical element sizes (MP + SExp).
| Case | 0.01-tolerance | 0.05-tolerance | (a) | Critical element size for = 1 m (b) | (c) | Critical element size for = 1 m (d) |
| Isotropic case | 50 | 0.02 m | 3.125 | 0.32 m | Layered case | 20 | 0.05 m | 2.5 | 0.4 m | Layered case | 20 | 0.05 m | 2.5 | 0.4 m |
|
|