Research Article

Performance Improvement of a Micro Impulse Water Turbine Based on Orthogonal Array

Table 1

Grid independence analysis.

Mesh scheme12345

Grid number378861569762114138923867574696273
Grid size/mm64210.5
η/%36.0335.0134.3234.0233.87
/m12.5612.3211.9711.9511.96