Research Article

Transfer Coordination for Metro Networks during the Start- or End-of-Service Period

Table 3

Dwell time sensitivity analysis and optimized results.

Optimized resultsThe headways: ±0 sThe headways: ±60 s
Dwell time 
±0 s
Dwell time 
±5 s
Dwell time 
±10 s
Dwell time 
±0 s
Dwell time 
±5 s
Dwell time 
±10 s

ATWT791 s751 s704 s735 s633 s596 s
PTFP36.6 %35.4 %33.1 %33.5 %29.4 %28.3 %
ATWT_TSP209 s176 s162 s198 s147 s121 s
Solution time108.43 s915.03 s4678.84 s306.89 s4591.52 s7200 s

The symbol “” means that the case is not solved to optimality within a time limit of two hours.