Research Article

Pump Selection and Performance Prediction for the Technical Innovation of an Axial-Flow Pump Station

Table 1

Comparison of performances between the original and selected pumps.

Blade setting angel
Flow ratePump headSpecific speedEfficiency
/(L/s)/(m)/%
Original PumpSelected PumpOriginal PumpSelected PumpOriginal PumpSelected PumpOriginal PumpSelected Pump

+43754444.455.221007102284.286.4
+23504164.435.19102099384.585.8
03304014.214.801033103484.085.7
-23053774.204.80996100283.785.5
-42803574.104.60972100783.185.3
-62503321.034.6093097182.085.1