Research Article

Durability Assessment of Lightweight Cellular Concrete in Subgrade by the Method of Analytic Hierarchy Process Combined with Fuzzy Comprehensive Evaluation

Table 2

Grade classification of influencing factors of construction technology.

Assessment gradeProduction equipmentAgitation sufficient degreeFlow value (mm)Single layer pouring thickness (m)Single layer pouring time (min)Interlayer pouring interval (time/hour)Construction environment

ExcellentExcellentExcellent[170, 180][0.3, 0.5]10 min before initial setting[8, ∞)Excellent
GoodGoodGood(180, 200](0.5, 0.7]5 min before initial setting[7, 8)Good
GeneralGeneralGeneral[160, 170)(0.7, 0.8]Initial setting time[6, 7)General
PoorPoorPoor(0, 160)(0.8, ∞)Greater than the initial setting time[0, 6)Poor