Distance (m)57.51012.51517.52022.52530

Measured data (mg/m3)249230246225327258271272304232
Simulated data (mg/m3)238218233208314244257254285217
Error rate (%)4.45.25.37.64.05.45.26.66.36.5

Note: “—” means that the air velocity is too small to be tested.

We are committed to sharing findings related to COVID-19 as quickly and safely as possible. Any author submitting a COVID-19 paper should notify us at help@hindawi.com to ensure their research is fast-tracked and made available on a preprint server as soon as possible. We will be providing unlimited waivers of publication charges for accepted articles related to COVID-19. Sign up here as a reviewer to help fast-track new submissions.