Mathematical Problems in Engineering / 2019 / Article / Tab 6

Research Article

Distribution Law and Prediction Model of Dust Concentration under Airflow Adjustment in Fully Mechanized Heading Face

Table 6

The hierarchy general ranking.

Rule hierarchyWeightsFactor hierarchyWeightsTotal sequencing weight

Adjustment parameters0.6250Distance from the duct outlet to heading face0.46730.292
Caliber of the duct outlet0.27720.173
Horizontal right deviation0.16010.100
Vertical upward deflection0.09540.060
Original gas and dust parameters0.3285Gas emission quantity0.57150.186
Dust production0.28570.094
Particle size0.14280.047
Ventilation parameters0.1365Air velocity at the duct outlet0.750.102
Ventilation volume0.250.034

We are committed to sharing findings related to COVID-19 as quickly and safely as possible. Any author submitting a COVID-19 paper should notify us at help@hindawi.com to ensure their research is fast-tracked and made available on a preprint server as soon as possible. We will be providing unlimited waivers of publication charges for accepted articles related to COVID-19. Sign up here as a reviewer to help fast-track new submissions.