Research Article

Artificial Bee Colony Optimization of NOx Emission and Reheat Steam Temperature in a 1000 MW Boiler

Table 5

HV indicator and time consumption by MOEAs.

LoadsMOEAsrHVTime consuming (s)

650 MWMO-ABC(1200, 0.002)0.357436.503
NSGA-II(1200, 0.002)0.289237.021

800 MWMO-ABC(500, 0.002)0.148138.105
NSGA-II(500, 0.002)0.106237.929

850 MWMO-ABC(500, 0.002)0.123930.856
NSGA-II(500, 0.002)0.059029.499