Times between failures for slurry pump P1 in hours.
| No. of failures | Time between failures (h) | No. of failures | Time between failures (h) |
| 1 | 434.09 | 16 | 375.05 | 2 | 226.04 | 17 | 496.48 | 3 | 266.67 | 18 | 649.41 | 4 | 681.33 | 19 | 540.68 | 5 | 1127.85 | 20 | 491.59 | 6 | 634.69 | 21 | 947.31 | 7 | 474.84 | 22 | 718.78 | 8 | 38.72 | 23 | 953.63 | 9 | 31.89 | 24 | 182.2 | 10 | 711.52 | 25 | 391.55 | 11 | 726.9 | 26 | 327.71 | 12 | 574.15 | 27 | 986.04 | 13 | 1043.54 | 28 | 352.53 | 14 | 336.54 | 29 | 631.86 | 15 | 771.23 | 30 | 680.52 |
|
|