Research Article

Main Girder Deflection Variations in Cable-Stayed Bridge with Temperature over Various Time Scales

Table 3

Comparison of measuring and calculated values.

Monitoring positionsCalculated values in model (kN)Measured values (kN)Relative error (%)

Cable 21457.8465.8−1.7
Cable 20482.0507.0−4.9
Cable 19465.9459.41.4
Mid-span deflection42.944.33.2
Vertical one-order frequency0.26190.2637−0.7