Research Article

Digital Instantaneous Frequency Measurement of a Real Sinusoid Based on Three Sub-Nyquist Sampling Channels

Table 2

Implementation results for FFT and frequency deduction algorithms.

SNR (dB)LComparison between FFT and frequency deduction
FFTFrequency deduction
N_FFTRMSE (MHz)Latency (ns)XRMSE (MHz)Latency (ns)

108102415.77310790410.239105
204815.7352108088.477125
1610245.2691079546.831110
20485.1812108586.237130

20810249.5001079042.262105
20489.5222108081.670125
1610243.1611079541.219110
20483.0392108580.967130

30810248.6651079040.676105
20488.6892108080.487125
1610242.8471079540.339110
20482.7392108580.251130