Research Article

A Continuous-Discrete Finite Memory Observer Design for a Class of Nonlinear Systems: Application to Fault Diagnosis

Table 2

Fault signature for different faults.

Different faultsStart instant (vertical dash line)End instant (vertical solid line)SignatureDetect instant

A bias on (F1)101
A bias on (F2)011
A bias on (F3)101
Actuator fault (F4)101