Tissue parameters used in eye and head thermal dosimetry models.

Tissue (g/m3) (J/kg/°C) (W/m/°C) (W/m3/°C) (W/m3)

Brainstem104336000.5033500010000
Cerebellum103936800.5653500010000
Head skin105035000.42091001000
Liquor103538400.53000
Skull190013000.30010000
Mandible190013000.30010000
Grey matter103936800.5653500010000
Anterior chamber100339000.58000
Choroid106038400.53000
Ciliary body104034300.4982700690
Cornea107642000.58000
Iris104034300.4982700690
Ligaments104033000.4202700690
Ora serrata92025000.250520180
Posterior chamber100039970.57800
Retina103936800.5653500010000
Sclera117042000.580135000
Vitreous body100939970.59400
Lens-I110030000.40000
Lens-II110030000.40000
Lens-III110030000.40000
Lens-IV110030000.40000
Lens-V110030000.40000