Research Article
A Combined Upper-Sided Synthetic S2 Chart for Monitoring the Process Variance
Table 4
Comparisons of the combined upper-sided synthetic
S2 chart and several run rules
S2 charts when
.
| | | | | 2-of-3 | 3-of-4 | 4-of-5 |
| 5 | 1.2 | 33.88 | 44.29 | 43.83 | 44.96 | 1.4 | 9.49 | 12.90 | 13.72 | 14.92 | 1.6 | 4.72 | 6.58 | 7.54 | 8.63 | 1.8 | 3.09 | 4.44 | 5.41 | 6.43 | 2.0 | 2.33 | 3.48 | 4.45 | 5.44 | 2.2 | 1.92 | 2.97 | 3.94 | 4.92 | 2.4 | 1.67 | 2.68 | 3.64 | 4.63 | 2.6 | 1.50 | 2.49 | 3.46 | 4.44 | 2.8 | 1.38 | 2.36 | 3.34 | 4.32 | 3.0 | 1.30 | 2.28 | 3.26 | 4.24 |
| 10 | 1.2 | 17.78 | 22.60 | 21.62 | 21.89 | 1.4 | 4.62 | 6.15 | 6.75 | 7.56 | 1.6 | 2.43 | 3.46 | 4.27 | 5.17 | 1.8 | 1.72 | 2.64 | 3.53 | 4.47 | 2.0 | 1.40 | 2.31 | 3.25 | 4.21 | 2.2 | 1.24 | 2.16 | 3.13 | 4.10 | 2.4 | 1.14 | 2.09 | 3.07 | 4.05 | 2.6 | 1.08 | 2.05 | 3.04 | 4.03 | 2.8 | 1.05 | 2.03 | 3.02 | 4.02 | 3.0 | 1.03 | 2.02 | 3.01 | 4.01 |
|
|