Research Article
Optimization of Multiobjective Configuration of Multienergy Microgrid Based on HMM and Typical Scenarios: A Case Study of Smart Park
Table 5
The probability parameters of the typical scene.
| Scene type | Scene 1 | Scene 2 | Scene 3 | Scene 4 | Scene 5 | Scene 6 | Scene 7 | Scene 8 | Scene 9 | Scene 10 | Scene 11 | Scene 12 |
| System electrical load average (kW) | 2103 | 2462 | 2985 | 1984 | 3057 | 2563 | 3323 | 2676 | 2478 | 2632 | 2279 | 2853 | System thermal load average (kW) | 4526 | 4987 | 5857 | 3793 | 3296 | 4087 | 3089 | 4390 | 4216 | 4957 | 5313 | 3255 | System cooling load average (kW) | 1924 | 1521 | 963 | 1262 | 2675 | 2019 | 2983 | 1643 | 1932 | 2488 | 2628 | 1585 | Average price of upstream wholesale market (yuan) | 0.34 | 0.26 | 0.64 | 0.63 | 0.71 | 0.56 | 0.53 | 0.41 | 0.79 | 0.65 | 0.78 | 0.68 | Mean wind speed (m/s) | 7.6 | 5.7 | 6.2 | 6.8 | 4.1 | 7.0 | 5.1 | 9.6 | 8.5 | 9.1 | 6.9 | 6.6 | Mean radiation intensity (kW/m2) | 0.75 | 0.52 | 0.24 | 0.79 | 0.87 | 0.49 | 0.63 | 0.43 | 0.76 | 0.79 | 0.35 | 0.45 | Scene occurrence probability | 0.13 | 0.07 | 0.15 | 0.02 | 0.06 | 0.06 | 0.07 | 0.05 | 0.06 | 0.15 | 0.06 | 0.07 |
|
|