Research Article

Computational Fluid Dynamics Analysis of Flow Patterns, Pressure Drop, and Heat Transfer Coefficient in Staggered and Inline Shell-Tube Heat Exchangers

Table 3

Outlet temperatures of shell-tube heat exchanger.

ZoneSTHX with inline tube structure (°C)STHX with staggered tube structure (°C)

Shell inlet20.0020.00
Shell outlet35.3342.93
Tube inlet85.0085.00